Question
Answer
Is the Von Duprin 6111 electric strike compatible with Von Duprin XP98/99 rim exit device?
Resolution:
This is not a recommended application as the electric strike does not have the same holding force as the XP98/99 rim exit device. Typically the XP device will withstand a higher force than electr...:
What is the part number for the Schlage thumbturn rim cylinder?
Resolution:
The rim cylinder with thumbturn, XB11-979 (Figure 1) was designed to be installed on the inside head of the Von Duprin 98/99–2 double cylinder exit devices, see Figure 1. The rim cylinder with...:
How does the Von Duprin 98/99 rim or vertical rod exit device with lever trim convert from L to L-NL function?
Resolution:
To convert the Von Duprin 98/99 Rim or Vertical (Rod or Cable) Exit Device with functional lever (996L-R/V) to act like a rigid lever (996L-NL-R/V) with key over ride follow these steps: R...:
Is the Von Duprin 1609 strike fire rated for pairs of doors?
Resolution:
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...:
What electric strikes are available for Von Duprin rim exit devices?
Resolution:
The 22, 33/35A and 98/99 rim exit devices: The 6111 is the most common electric strike to be used with these devices 6112 and 6113 electric strikes also could be used The 6300 surface mount el...:
Can the CD and EL options be provided on the same 98/99 rim or vertical rod exit device?
Resolution:
There is not enough room for both Cylinder Dogging (CD) and Electric Latch Retraction (EL or QEL) options because they both try to occupy the same space in the device.The dogging mechanism for cyli...: