Right hand closure parallel arm
”
RELATED FAQS
Question
Answer
What is the difference between an LCN CUSH arm, and an LCN EDA arm?
Resolution:
EDA ARM - The EDA arm is a heavy duty parallel arm mount. The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...:
Can a 4041 EDA be mounted top jamb?
Resolution:
The 40401/4040XP closer with optional EDA arm has to be mounted parallel arm on the push side of the door.:
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
What do I need to do to make my 4041 Reg/PA a hold open arm?
Resolution:
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...:
Where is the RA closer reinforcement located on a frame for a Regular Arm Closer?
Resolution:
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...:
Can you mount a 4011 as a parallel arm like the 4111?
Resolution:
The 4011 can only mount on the Pull Side of the door and the 4111 can only mount on the Push Side of the door. Differences - The 4011 and the 4111 cylinders are different and the pinion shafts are...:
How can I make my regular arm closer mount parallel arm?
Resolution:
This can only be done with universal, non-handed closers: 1250, 1260, 1450, 1460, 4030, 4040XP, and 4050A.You would need an xxxx-62PA shoe to adapt from regular arm to parallel arm mount...:
How do I determine the hand of a door?
Resolution:
Go to the push side of the door opening. See above illustration. If door swings out to the left, it needs a left hand door closer. If door swings out to the right, i...:
PARALLEL ARM HOLDER
Resolution:
PAH:
PARALLEL ARM
Resolution:
PA, push side mount:
RIGHT HAND REVERSE BEVEL
Resolution:
RHR:
Why does the arm of my 4110 EDA touch the door when it is closed?
Resolution:
If the closer arm is touching the door, it is because the arm or the closer body is not templated correctly. Confirm dimensions are taken from the proper location and make corrections if needed. :
In what direction should the hold open nut be pointing for a 4041 H closer, up or down?
Resolution:
Make sure that the hold open nut is not on upside down. The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...:
Do I have to couple each lock with the HHD/SUS after the coupling password is changed or updated?
Resolution:
After updating the SUS coupling password, subsequent HHD’s will need the new coupling password entered before they can update any information in the lock, once the HHD has the correct coupling pass...:
How do I change the handing on my 7500 mortise lock?
Resolution:
You can reference the 7500 mortise lock rehanding instructions. Remove the two screws from mortise lock faceplate. Remove the face plate and the collar from the mortise lock then rotate the la...:
Why is my HHD not connecting to my AD lock?
Resolution:
5) If working with a CO lockset, the mechanical key switch needs to be in its "Inactive" or normal position. Ensure the triangle alignment on the front escutcheon and that...:
Why can't I see the Lock Friendly name in the Hand Held Device (HHD)?
Resolution:
In order for the HHD to be able to display the lock name, the lock firmware must be updated with ADFwPkg 2.17.10 and COFwPkg 1.21.0 (OR higher) AND the lock MUST be programmed with its door file be...: