return door lock

RELATED FAQS

Question
Answer
Issue: One or both levers don't stay horizontal and droop down.Facts: Falcon T series locks in a high use application.Cause: Weak or broken springs within the springcage.Solution: Replacement sprin...
This change was implemented in firmware package CO.A.6 (or later) to help the customer in the communication and coupling process between the CO200 (CO250) and the hand held device (HHD). ...
The green LED is to be lit up until the spindle (Triangles and Key Switch) are aligned properly; providing a visual indication of the problem.  
If the mechanical alignment of the triangles on the back of the outside escutcheon are not aligned, the CO200 or CO250 will not connect with the SUS/HHD and will appear to be unresponsive...
In firmware CO.A.6 (or later) the Schlage button on the CO200 (CO250) will turn green anytime that the spindle triangles on the front escutcheon are out of alignment or the mechanical key switch is...
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...
There is potential for ND40/ND44's manufactured around March 2011 to remain locked after egress, or after the latch is depressed.  There was an issue with the keycam that created a bind when l...
The lever return distance (tip of lever to door face) on the Jupiter lever design is approximately 1-3/4".
See Falcon MA lever assembly below: The spring mechanism (E) returns the lever to horizontal.  The parts are not sold separate, so if the lever sags, the entire lever assembly shoul...
Lever assemblies part numbers are found in the Pricebook.  Note they are handed.