replace old chexit

RELATED FAQS

Question
Answer
For Chexit devices with solenoid driven shipped from the factory prior to 8-24-2015, the RX switch is ordered as a "Special CX RX Switch".  It may only be installed or adjusted ...
Part number for Von Duprin standard 15 sec. release Chexit module shipped after 8-24-2015 with motor driven is 040086-00. Part number for Von Duprin standard 15 sec. release Chexit module shi...
If the horn fail to operate in the CX device you need to replace the Chexit module. 040086 is the part number for devices shipped after 8-24-2015 with motor driven.050228 is the...
For motor driven Chexit devices shipped from the factory after 8-24-2015, the RX switch is replaceable as part number 116717-00. Note:  A slight change to the plastic housing was ad...
For solenoid driven Chexit devices shipped from the factory prior to 8-24-2015, the RX switch is no longer available.  This part was discontinued in 2019. If the older version Chexit RX s...
The Chexit device has a different base plate and center case than the ALK.  The Chexit device would need to be replaced with an ALK device.
The release delay time for the Chexit is programmed into the Chexit module and cannot be changed in the field. The ability to change the delay time is restricted by the UL listing of the devi...
The standard Von Duprin mechanical or electrical 98/99/33/35 exit devices can NOT be converted to a CX98/99 or CX33/35 device. Von Duprin CX98/99 or CX33/35 have a...
Chexit motor driven devices shipped after 8-24-2015:You can use 1 Chexit device with PS902, 3 Chexit devices with PS904, and 4 Chexit devices with PS914 or PS906 power supplies with proper gau...
The E996L-FSE trim is needed if the application requires fail-secure operation from the trim side of the opening. When power is out on Chexit device, E996L-FSE trim will remain locked to ...
Most Panic devices are not designed for exterior applications. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish an...
For Rim / Vertical Devices: No,  RX 996 trim can not be used to inhibit Chexit.  The trim lever can not be rotated while the Chexit is armed, and therefore the RX996 switch will not...
Schlage Electronics 1910 series horn can be used as an external horn with Von Duprin Chexit device.
The EL Wiring Adapter is not needed for a CX device.
The NL key override will not open the door while Chexit rim or vertical rod device is in the arm mode.
You can use the E996L electric trim with Chexit 98/99 series exit device.
The Von Duprin PS873-2 power supply replaced the old Von Duprin PS871 power supply. The Von Duprin PS914-2RS power supply replaces the PS873-2 or PS871 power supply and is currently the supply r...
The 33/35 series can be replaced with 33A/35A with a small modification to the door.  See the template, 33A Retrofit Preparation, for the necessary modification to the door and ...
The LCN 4010SE / 4110 SE series are obsolete, and on longer available. They were replaced by the 4040SE series. The 4010SE / 4110 SE track is replaced with the current 4040SE trac...