removable transom panel

RELATED FAQS

Question
Answer
GrainTech® doors are not available with different finishes on the inside and/or the outside door panels. Both panels must match. Standard GrainTech® finishes include: Birch Ash Oak Maple Ma...
Transom panels are available in the following constructions: 1 3/4" thick panels with interior construction similar to an L-Series door installed into a frame either Without a transom bar - r...
Update the PIB300-2D firmware to version 2.13.1 or higher to be compatible with Brivo Access Panels
Update the PIM-400-TD2 firmware to version 2.14.2 or higher to be compatible with Brivo Access Panels
Steel transom panels are available: 1 3/4" thick panels - supplied in L-Series (L20, L18 or L16-Series) laminated construction. Recommended down sizing is as follows: Without Transom Bar 3...
The SUS can change the logic polarity of the AD400/WRI400 PIM400-TD2 outputs RTX, DPS, TROUBLE, and REN from LOCK/DOOR PROPERTIES Edit tab. You can change High to Low to High using the ed...
  These SUS settings have no effect when the AD400 is linked to a PIM400-485; because the PIM400-485 reports the logic status with RSI-485 commands and not logic levels. The settings are gray...
Panel
The following anchors are approve for use in FEMA Tornado Resistant openingsMasonry walls:Jamb anchors - Wire masonry anchorsSill (base) anchors - Adjustable base anchorsExisting walls:Jamb an...
Removable transom bars are available for non-rated frames. A closed section mullion available. Special clips to attach to frame sold separately. Removable transom bars are not approved or avai...
The 419 panel adaptor is the replacement for both the obsolete 145 shoe, and 418 panel bracket (both were made obsolete in 2009). The 419 panel adaptor is 4" wide, 2" tall, and projects 3". ST-069...
Knock Down (KD) frames: KD frames are designed, manufactured and supplied with integral miters which include all notches, interlocking corner tabs and slots to allow for field assembly and do not r...
High Definition (High Def) door panel designs have deeper shadow lines than conventional CE-Series designs. CE-Series doors are available with optional High Definition (HD2 and HD2A) door panel de...
Transom Frame, Side Light Frame, Transom and Side Light Frame, Transom Panel Frame, Side Panel Frame, Transom and Side Panel Frame, Borrowed Light Frame
Types of astragal offered from Steelcraft are as follows: "Z" Astragal - For information on "Z" astragal types and attachment refer to the TD Manual page 3.3.17. Most commonly used on double ...
Steelcraft doors and/or frames do not contain any asbestos. Steelcraft did use asbestos in the following products: Steelcraft S16-Series stile and rail door with flush panel and UL fire door l...
Transom Panel, Rabbeted Transom Panel
Transom Panel, Transom Light
The 4110 series closer is installed on a flush transom frame using the -419 flush panel adapter.
The 4040 XP CUSH/EDA can be mounted on a Flush Transom frame by using a -419 Flush Panel adapter.
Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...
An Astragal is an applied molding attached most commonly to the meeting edge of doors to: Protection against weather conditions Minimize the passage of light between the doors Retard the passa...
Side Light and Side Panel frames - Side Light and Side Panel frames are not KD (Knock Down), they must be assembled and welded. All side lite and side panel frames must be assembled and welde...
Closed Section, Mullion, Removable Transom Bar
NO - Louvers are not approved for installation in a fire rated transom / side panel frames.  NFPA Pamphlet 80 - paragraph # 6.3.4.4 states “Louvers shall not be installed in either transom or s...
CE Series door in a variety of embossed panel designs and gages. The CE series embossed panel doors also offer a wide range of specifiable options including sizes, glass light designs and hardw...
Maximum hourly rating for a transom and side light or panel frame is 1 1/2 hour (90 minutes). In masonry wall application the maximum is 13'6" x 12'2" In stud wall application the maximum is 13...