RABBET TOP DOORS
”
RELATED FAQS
Question
Answer
Why are lead lined frames used?
Resolution:
Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows: Frames are supplied knock-down (KD). Fram...:
DOOR RABBET
Resolution:
Rabbet, frame feature; Frame Profile?:
DOUBLE RABBET FRAME
Resolution:
Frame with a recess or offset formed on both sides of a stop to receive a door:
RABBET
Resolution:
Recess or offset formed in the face to receive a door:
What is the standard downsizing for a door leaf when using continuous hinges?
Resolution:
Doors require special downsizing for continuous hinges. The amount of downsizing depends on the hinge specified (manufacturer and type) and the hinge application (Full Mortise versus Full Surface v...:
Where is the Fire Label located on a door and a frame?
Resolution:
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the fram...:
What are the standard door and frame clearances?
Resolution:
To determine Actual Door Size, the following values are subtracted from nominal door size (frame opening/order size) Actual Door Size: The largest measured width by height of the door leaf as m...:
Door hitting the strike jamb?
Resolution:
If the door hits the frame (or rubs on the rabbet of the head or jamb) the frame is out of square and improperly installed. Door edge rubbing on the rabbet - shimming the hinges may resolve the...:
What is the hinge backset for 1 3/4" thick door?
Resolution:
Hinge backset is the dimension from the leading edge of the hinge to either the stop on the frame or to the stop face (push side) of the door. For operating clearance, the hinge backset on the d...:
Can a 4640 operator be mounted on a Flush Ceiling application?
Resolution:
4640 Flush Ceiling mounting requires a minimum 1-3/4" Header, and a minimum 3-3/4" Top Rail on the door.: