Question
Answer
How many Von Duprin QEL devices can be connected to a power supply?
Resolution:
Product Ordered before 7/10/2012 - Product identified by no label on QEL motor. You must use the 900-2Q option board with the PS900 power supplies to operate the QEL devices. The attached ta...:
Can I run 4 QEL devices from one PS902?
Resolution:
No, you can only add one 900-2Q option board to the PS902 power supply and 900-2Q only can support two QEL devices.:
Will the MPB-842 or MPB-840 power EL or QEL devices?
Resolution:
The old MPB842 power supply will power up to two EL electric panic bars but will not power the QEL devices. A defective potted module inside the electric panic bar or defective power supply coul...:
Does the QEL retract the latch bolt and the pushpad?
Resolution:
Yes the Von Duprin QEL exit device retracts the latch bolt and pushpad. Pushpad and latch bolt stay retracted as long as power is applied to the QEL exit device. :
What is the most common practice for running electric power from a frame to the door and hardware?
Resolution:
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into...:
Are EPT preps available on the Paladin Series door?
Resolution:
EPT power transfer preparations are available on the Paladin PW14-Series door and FP14-Series frame. Electrified hinges are available on the Paladin PW14-Series door&...:
Do we have a maximum door width or height for using pivots?
Resolution:
The maximum door width that pivots have been tested is a 4' wide door. Any door greater than 4' would shorten the life of the pivots. There is no maximum door height, for offset pivots the ru...: