QEL and wire hinges
”
RELATED FAQS
Question
Answer
How many Von Duprin QEL devices can be connected to a power supply?
Resolution:
Product Ordered before 7/10/2012 - Product identified by no label on QEL motor. You must use the 900-2Q option board with the PS900 power supplies to operate the QEL devices. The attached ta...:
What are the wire gauge and length requirements for QEL devices?
Resolution:
Use #18 gauge wire up to 200 feet maximum distance from PS900 x 900-2Q power supply to the QEL exit device. The new QEL+ no longer requires the 900-2Q board but still needs a different option board...:
Can electrified hinges be used on QEL devices?
Resolution:
The electrified hinge can be used on QEL exit devices.:
Can we do TW on swing clear hinges?
Resolution:
Swing clear hinges are available with TW (through wire).:
Does the wire size of an EPT affect the operation of an EL device?
Resolution:
Since most wire transfer devices such as an EPT or electric hinges cannot provide large gauge wires, we take the small gauge wire into account when determining the overall wire size for the device....:
Can you have a security stud hinge with a TW option?
Resolution:
The Security Stud and TW4/8 (through wire) options are in the same location on a hinge and cannot be ordered together.: