No stop frame
”
RELATED FAQS
Question
Answer
Are hospital stops approved on fire rated frames?
Resolution:
Yes, hospital stops are available on fire rated frames. Maximum approval = 3 hour Maximum sizes: singles up to 4'0" x 8'0" pairs up to 8'0" x 8'0" Maximum hospital stop height 6" from bot...:
What wire gauge and run is recommended for Von Duprin electric latch retraction EL device?
Resolution:
:
Are factory finished doors and frames available from Steelcraft?
Resolution:
Factory finished painted doors are available from Steelcraft. Frames "are not available" factory finished from the factory. Doors are offered in variety of standard colors or can be fini...:
Can steel frames be installed after the wall board is installed in stud wall applications?
Resolution:
DW and K-Series frames are designed to slip onto a stud wall after the wall is finished (painted, wall papered, etc).Walls can be either wood stud or steel studUsed only for interior appl...:
What is a 45° Hospital Stop?
Resolution:
Hospital Stops are available as either: 45° Hospital Stop - the stop of the frame terminates at a 45° angle 90° Hospital Stop - the stop of the frame terminates at a 90° angle The type of hos...:
What electric strike can be used with the 1790?
Resolution:
None of the Von Duprin electric strikes will work in a retrofit application where the normal standard mechanical strike is mounted to the frame because none of them are thin enough to fit in...: