new von dupri push

RELATED FAQS

Question
Answer
If the Chexit device shipped prior to 8-24-2015  is not adjusted correctly ( Check vertical rod or Mortise finger) without using the door position switch and nuisance delay is&n...
 
The following may cause the ALK to go into alarm: Make sure red and blue wires on the RX switch are connected to the exit alarm ALK terminal block and yellow wire is taped off. Check the red an...
You cannot lock the push side of the exit device as a panic device by design must allow exit.  Any attempt to block an exit is forbidden by code.
If the 9100 Series Benchmark operator does not open when the actuator is pushed: Verify the unit has 120 volts applied to it. Verify the the power light on the control box is on. If not, check ...
No, the back plate for 880K-knob trim is the same as for 373L-lever trim. Since 373L is a narrow style trim it require to use the 889 cover plate with this trim.
The standard Von Duprin PS873 power supply was replaced by the PS914 power supply.
NOTE: The newer PS900 option cards can NOT be used in the PS873 power supplies. The PS873 option cards also can NOT be used in the newer PS900 series power supplies.
Attached tables are power supply cross reference, power supply option board and power supply option board compatibility. PS900-Model PS900-Summary Legacy Supply (PS873) PS902 &...
PS900- Model PS900-Summary Legacy supply (PS873) 900-2RS 2 zone control with sequencing 871-2 board 900-2Q 2 zone control for QEL 2Q board 900-4R 4 relay control, no timin...
Option Board Von Duprin PS914 Schlage PS902, PS904, PS906 900-2RS Yes No 900-2Q Yes Yes 900-4R Yes Yes 900-4RL Yes Yes 900-8F Yes Yes 900-8P Yes Yes 900-B...
Yes, Von Duprin 996L lever handle can be replaced with a new one . Attached installation instructions shown how to replace the existing lever handle on 994/996L trim for rim and vertical rod device...
Schlage and Von Duprin introduced the new M Collection of decorative levers in January 2014.Click here to visit the new webpage.
Recommend to order a new 990NL-R/V or M trim to change from TP/Classroom function to NL/Storeroom function. You will also need to reinstall the NL drive screw back into into the mast...
Changing the handing on a Von Duprin 373L trim requires following parts: LHR to RHR requires 090092 ( Package of 4 springs ) and 050597 ( back plate assembly ). RHR to LHR requires  090091 ( Pa...
Changing the handing on a Von Duprin 373L trim requires following parts on all lever designs EXCEPT #12: RHR requires part number 090092-00 (LEVER CONTROL SPRING RHR PKG/4) and 050597-...
The VD 7308/7311/7321/7322 were replaced by the KP212 Von Duprin 7311 and 7321 key pads were discontinued and there are not direct replacements Von Duprin no longer sells key pads, contact Schl...
A PBKIT is a Pushbar Retrofit Kit.The pushbar retrofit kits are not the same for 33A/35A and 98/99 series exit devices.  Depending on the finish of the exit device, the pushbar end caps are di...