Astragals are required on:
3 hour fire rated pairs:
Double doors - swinging in the same direction
Double Egress - swinging in opposite directions
Fire rated Dutch Doors
Fire rated 1 3/4" t...
Steelcraft
frames and doors are furnished with a high grade, low gloss, baked-on prime
paint that provides the best possible protection against corrosion, abrasion
and weather, and is an excellent ...
Elevation frames are available in:
F-Series (F16 or F14)
FN-Series (FN16 or FN14)
MU-Series (MU16, MU14)
Additional parameters of the frame components:
Perimeter (Head and Jambs) Frame:
...
Transom panels are available in the following constructions:
1 3/4" thick panels with interior construction similar to an L-Series door installed into a frame either
Without a transom bar - r...
No. Fire rated double egress frames must be a stand alone 3 sided frame assembly.
If transom lights and/or sidelights are required, they must be built and installed as separate Fire Window assemb...
NO - Louvers are not approved for installation in a fire rated transom / side panel frames.
NFPA Pamphlet 80 - paragraph # 6.3.4.4 states “Louvers shall not be installed in either transom or s...
To mount the 6030 series closer in a hollow metal frame, the frame has to be a "cased open" frame (meaning no stops formed in the frame) because the 6030 series closer is a double acting closer, wh...
Yes, wood doors can be used and installed in most hollow metal frame applications including FE-Series and DE-Series Double Egress frames.
Caution - For fire rated applications the wood door manufa...
ASTM E-119 is a test standard for walls, partitions and floor or roof systems:
This test standard is also used for ceramic type glasses when used as window wall and/or borrowed light frames.
...
On fire rated transom and/or sidelight frames and fire rated window frames, Steelcraft labeling procedures only control the O/A width and/or height of the frames based on wall condition. The amount...