MAXIMUM SIZE FRAME

RELATED FAQS

Question
Answer
The following size limitations per frame unit, are in enforced for welded elevation frames shipped from the factory. These limitations are in place due to the physical size of shipping tr...
Maximum hourly rating for a transom and side light or panel frame is 1 1/2 hour (90 minutes). In masonry wall application the maximum is 13'6" x 12'2" In stud wall application the maximum is 13...
On fire rated transom and/or sidelight frames and fire rated window frames, Steelcraft labeling procedures only control the O/A width and/or height of the frames based on wall condition. The amount...
ITS/WHI Fire Rated three (3) frames are available in the following maximum door opening sizes: F and FN-Series: 4' 0" X 10' 0" single door 8' 0" X 10' 0” double door or pairs MU-Series: ...
Fire Rated three (3) frames are available in the following maximum door opening sizes: F and FN-Series frame: 4' 0" X 10' 0" single door opening 8' 0" X 10' 0” double door opening MU-Ser...
DW-Series Fire Rated Borrowed Lights are available in the following sizes: 60 minute (1 hour) rating = 2721 square inches of visible glass. maximum frame rabbet to rabbet dimensions = 78 1/4...
Steelcraft uses a 7 gage hinge reinforcement for 4 1/2" and 5" butt hinges as standard on all frame series. The hinge reinforcement size for either 4 1/2" or 5" hinges (standard or heavy duty hing...
The rough opening dimensions are the same for either Welded (SUA) or Knock Down (KD) frames For F, FN, FE, DE, MU three sided frames and four sided borrowed light frames: New masonry Walls: N...
 For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening height ...
Yes. 1 7/16" thick glass but a special rabbet size is required. The size of rabbet required for the frames would depend on the size of the glazing bead being used. For 1" wide glazing stops, ...
The 2010 and 2030 closer are not the same. The 2010 Series closer uses the (larger) 4010 cylinder which requires a 4" minimum frame tube to mount in. The 2030 uses the (narrow) "Pacer" cylinder...