Are masonry T anchor fire rated?
Resolution:
Masonry T anchor are approved for fire rated frames up to 3 hours. T Anchors are shipped lose for field installation. Anchor construction: The T portion and the strap do have minimum dim...:
JAMB DEPTH
Resolution:
Jamb Width:
Can a Glynn Johnson 90 stop be used with a top jamb mounted 4040?
Resolution:
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.:
Can a 4041 EDA be mounted top jamb?
Resolution:
The 40401/4040XP closer with optional EDA arm has to be mounted parallel arm on the push side of the door.:
TOP JAMB
Resolution:
Mounting with closer installed on frame face:
How many P & D (Pierce and Dimple) holes are in a frame?
Resolution:
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height: Quantity Nominal Frame Height 2 1'...:
JAMB WIDTH
Resolution:
Jamb Depth:
What is the difference between the FE and DE-Series frames
Resolution:
A Double Egress frame is a double door frame prepared to receive two single-acting doors swinging in opposite directions (both doors are) the same hand. These openings are installed in cross corrid...:
Can Steelcraft make a 12 gage hollow metal mullion?
Resolution:
Steelcraft does not manufacture 12 gage closed section mullions. The maximum is 14 gauge. Steelcraft can provide the outer perimeter (open sections only) of a transom frame in 12 gage material. ...:
How many compression anchors are provide per jamb on DW-Series frames?
Resolution:
For compression anchor details refer to the “ANCHORING SYSTEMS” section in the Steelcraft Tech Data Manual.Anchor Quantities: • 1 compression anchor per jamb through 9"depth • ...:
Can a 4040 open to 180°?
Resolution:
The 4040/4040XP closer mountings have the following maximum opening degree templating: The 4040/4040XP PA "Regular Arm" mount will allow for 180° max. opening. The 4040/4040...:
Can an additional jamb anchor be used as a base anchor on fire rated frames?
Resolution:
Yes, an additional jamb anchor can be used at the bottom of the frame in lieu of the typical (adjustable or weld-in) base anchor in fire rated frames. This is limited to the anchor designed for...:
Where is the RA closer reinforcement located on a frame for a Regular Arm Closer?
Resolution:
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...:
What is the difference between an LCN CUSH arm, and an LCN EDA arm?
Resolution:
EDA ARM - The EDA arm is a heavy duty parallel arm mount. The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...:
What anchors are used in FEMA Tornado Resistant openings?
Resolution:
The following anchors are approve for use in FEMA Tornado Resistant openingsMasonry walls:Jamb anchors - Wire masonry anchorsSill (base) anchors - Adjustable base anchorsExisting walls:Jamb an...: