max width for panic

RELATED FAQS

Question
Answer
The following size limitations per frame unit, are in enforced for welded elevation frames shipped from the factory. These limitations are in place due to the physical size of shipping tr...
Monorail cutouts are typically the upper corner of door. Channels are cut to size welded into door held flush to cutout. We do not supply any covers or plates to finish.
The size monorail cutout is 8" wide x 24" high
Monorail cutouts are only available for non fire rated applications.
The maximum door width that pivots have been tested is a 4' wide door.  Any door greater than 4' would shorten the life of the pivots. There is no maximum door height, for offset pivots the ru...
Maximum nominal (overall) single door sizes are as follows: L-Series (Laminated Door) 20 Gage = 3’ 0” wide X  8’ 0” high 18 Gage = 4’ 0” wide X 10’ 0” high 16 Gage = 4’ 0” wide X 10...
Butt hinges can be used on  doors up to 4' wide and 200 pounds.  There is no maximum door height, just need to add a hinge for every 30" or part there of over 7'.
The maximum width door the Steelcraft can make is 4' 0"
An EPT can be used with a Cam Lift Hinge: Maximum hinge lift dimension = 1/2".  The EPT must be installed correctly with the tube at the top on the door side and the tube at bottom on...
Panic Hardware and Fire Exit Hardware are two different types of exit devices, and the proper selection is determined by code requirements. Panic Hardware is an exit device which is tested for u...
The most obvious difference (in the device) is the lack of mechanical dogging on a Fire Rated Device.  There are some internal parts that may be different and the method it is secured to the d...
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb.          &nbs...
A standard exit device can't be modified to a fire rated exit device.  A new device must be purchased.
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...