Question
Answer
Can I get the RU series with a Schlage Full Size Interchangeable core?
Resolution:
The RU lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied. The tailpiece will come with the lock. Example: RU581J IC-SC:
What is the replacement for the Locknetics 9100 series electric strike?
Resolution:
The Locknetics 9100 series electric strikes are replaced with Von Duprin 6211 and 6210 electric strikes. The 6211 is used if the frame is being replaced. The 6210 is for ...:
What is the part number for T lock tailpiece used with a conventional cylinder?
Resolution:
Refer to Table 1 for a list of T lock tailpieces for conventional cylinders. Table 2 shows IC tailpieces. Table 1: T lock conventional tailpieces Table 2: T lock IC tailpieces:
Where can I find discontinued G lock templates?
Resolution:
Schlage G Series template locate here. :
Will a 25R-L cover the door prep from a 18-R-L?
Resolution:
The (4) center case mounting holes are in the same location but there are some small modifications that will be needed like the 3/4" dia. hole at device CL for the main cam clearance shown o...:
How to order a T series lock with a Corbin Russwin full size interchangeable prep.
Resolution:
Specify the J cylinder suffix followed by IC-CR6 or IC-CR7 (6 or 7 pin Corbin core) Example: T581J IC-CR6 This will accommodate an 8000 or 8000-7 Corbin Russwin Full Size core.:
What is the part number for the lever return spring for the MA lock?
Resolution:
Lever assemblies part numbers are found in the Pricebook. Note they are handed.:
Will the Von Duprin 6210 electric strike operate with the MA series locks?
Resolution:
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...:
What are the dimensions of the MA Series escutcheon?
Resolution:
The Falcon MA Series escutcheon is roughly 8.15" tall x 2.28" wide x 0.37" thick.:
Are the M and MA locks compatible?
Resolution:
No parts are compatible between the Falcon MA-Series and the obsolete Falcon M-Series.:
Are EPT preps available on the Paladin Series door?
Resolution:
EPT power transfer preparations are available on the Paladin PW14-Series door and FP14-Series frame. Electrified hinges are available on the Paladin PW14-Series door&...:
Is there an ADA thumbturn offered in the MA locks?
Resolution:
Falcon does not offer an "ADA style thumbturn.:
Will a Schlage L9000 thumbturn work on a Falcon MA lock?
Resolution:
The Schlage 09-509 Rose style thumbturns will work but the spindle sits 90 degrees off from each other (Schlage is square, Falcon is diamond). The result is the throw will end up 10 and 2 o'c...:
Can an additional jamb anchor be used as a base anchor on fire rated frames?
Resolution:
Yes, an additional jamb anchor can be used at the bottom of the frame in lieu of the typical (adjustable or weld-in) base anchor in fire rated frames. This is limited to the anchor designed for...:
How many P & D (Pierce and Dimple) holes are in a frame?
Resolution:
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height: Quantity Nominal Frame Height 2 1'...:
Falcon MA Series
Resolution:
Grade 1 mortise lock:
MA lock case dimensions.
Resolution:
See below for commonly requested dimensions on the MA lock. Dimensions not found in other literature have a square around them. CL refers to "Centerline". :
How do I remove the lever on an M lock?
Resolution:
To remove the M lock trim follow the steps below in reverse. The M lock spanner wrench is 021415. Although this wrench is no longer available from&n...:
Will the Falcon MA lock fit a 1-3/8" thick door?
Resolution:
The Falcon MA will not fit a 1-3/8" thick door. :
Can I get the T series with a Schlage Full Size Interchangeable core?
Resolution:
The T lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied (including the tailpiece) Example: T581J IC-SC: