Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
lx switch cables
”
RELATED FAQS
Question
Answer
What should I do if the CT5000 USB cable gets disconnected during a firmware update?
Resolution:
If the SUS has timed out (after a few seconds), do the following: Reconnect the USB cable; When communication has been re-established, Select "Device Options" at the bottom of the Schlage...:
What is the wire gauge on the motor driven L9000 mortise locks?
Resolution:
Supply wires - 24AWGRX wires - 20AWGLX wires - 20 AWG:
What is the difference between Von Duprin LX and/or RX switches and the Signal Switch SS option?
Resolution:
The RX monitors the push bar while the LX monitors the latch bolt of the exit device. A SS device has an LX and a key cylinder switch plus an emergency push bar signage.:
Can a pneumatic (PN) 33A/35A/98/99 exit device use the RX or LX switches?
Resolution:
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.:
What power supply is used with RX or LX switches?
Resolution:
The RX switch is request exit and the LX switch is latch bolt monitor switch. They do not require a power supply directly. The electrified hardware that the RX or LX switch...:
What are the Von Duprin part numbers for RX, LX and RX,LX-LC switch kits for field installation?
Resolution:
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.:
Why should you use the LX switch with an ALK being used in Von Duprin surface vertical rod devices?
Resolution:
An RX switch would only trigger the ALK Alarm Kit when the pushpad of the device is depressed.Surface Vertical Rod (SVR) Devices such as the 2227, 33/3527A, 98/9927, and 98/9957 devices could be op...: