Question
Answer
What are the Von Duprin part numbers for RX, LX and RX,LX-LC switch kits for field installation?
Resolution:
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.:
Can QEL and RX be added to an existing 9927?
Resolution:
The QEL conversion kit (3' or 4') and the RX switch kit (050251-00) can convert the 9927 to QEL-RX9927 device.:
Is it possible to have EL/QEL and an exit alarm on the same device?
Resolution:
It is not possible for an exit device to have an EL/QEL component and an exit alarm. There is not enough room in the device to house both items.:
Can you convert the EL33A/35A or EL98/99 series exit device to the QEL device?
Resolution:
The Von Duprin EL33A/35A/98/99 device can be converted to the QEL device by getting the correct sized QEL baseplate conversion kit. The existing PS914 or PS873 power supply can be used. ...:
Can the Von Duprin exit alarm ALK and electric latch retraction QEL or EL device be in the same device?
Resolution:
No, Von Duprin exit alarm ALK and electric latch retraction QEL or EL are installed in the same location and can't be ordered together with the same device.:
Why would QEL retract and release repeatedly?
Resolution:
The following could cause the QEL device to retract and release repeatedly: If this is a vertical rod type device, the vertical rods could be adjusted too short. Check rods for dead locking, ...:
How much amperage does the QEL draw?
Resolution:
Applies only to Von Duprin QEL exit devices shipped after December 11th, 2014.1.0 amp inrush and a 0.14 amp holding current.:
Will the 900-2Q option board operate an EL device?
Resolution:
The 900-2RS is recommended to be used with EL devices but if you have a 900-2Q with PS914 power supply it can be used to operate up to two EL or one EL and one QEL devices .:
What is needed to keep the EL device retracted all day?
Resolution:
To keep the Von Duprin electric latch retraction EL or QELA exit device dogged (retracted) all day, have your access control, Key pad, key switch, fire alarm contact or any other signals ...:
Can a pneumatic (PN) 33A/35A/98/99 exit device use the RX or LX switches?
Resolution:
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.:
Is there a template that shows where to drill the hole for E/EL/SS/RX/LX/CX wires?
Resolution:
The hole should be drilled in the field once the end cap is located on the door. It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...:
What is the difference between Von Duprin LX and/or RX switches and the Signal Switch SS option?
Resolution:
The RX monitors the push bar while the LX monitors the latch bolt of the exit device. A SS device has an LX and a key cylinder switch plus an emergency push bar signage.:
Can you add the LX option to a Von Duprin device that already has the RX option?
Resolution:
The Von Duprin RXLX combination switch must be ordered together as one assembly. Existing RX or LX switch must be removed to install the combination RX LX switch. Make sure correct RX LX combinatio...:
What power supply is used with RX or LX switches?
Resolution:
The RX switch is request exit and the LX switch is latch bolt monitor switch. They do not require a power supply directly. The electrified hardware that the RX or LX switch...:
Will the QEL+ still work with the 900-2Q?
Resolution:
You can use the QEL+ device with 900-2Q option board. The 900-2Q board is obsolete with no stock remaining. :
Why is my QEL device not retracting completely?
Resolution:
You may have a defective motor bracket, defective base plate or vertical rod could be out of adjustment.:
Will the PS900-2 RS operate the Von Duprin QEL device?
Resolution:
See below for QEL device requirements: QEL devices shipped prior to 7/23/12 must have the 2Q option board for the communication link between the power supply and the exit device. &nb...:
How far down can an exit device be cut down in the field?
Resolution:
For most exit devices, please refer to the specific device series catalog for minimum door opening width the device can be cut down to fit. Be aware that some device options, frame...:
How many times can an EL device be operated when using a PS914-2RS with battery backup?
Resolution:
The Von Duprin PS914-2RS retracts the EL or QEL device approximately 200 times with five second hold time after each pull.:
What is (SD) Special Dogging?
Resolution:
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.:
Is the SD option available with Von Duprin QEL 98/99 exit devices?
Resolution:
SD option is available and is also standard with Von Duprin 98/99 rim and vertical rod exit devices but not available with mortise device.:
Why does the QEL cycle 3 times with a solid red led and does not work?
Resolution:
Improper mechanical adjustment or QEL calibration could cause the QEL cycle three times with solid LED and not work. First check mechanical adjustment on vertical rods or mortise lock device and co...:
Will there be 900-2Q boards for warranty purposes now that the QEL'S do not require the boards?
Resolution:
The 900-2Q board is no longer available. For warranty purposes, QEL conversion kit and 900-2RS board are required. The 900-2RS replaces the 900-2Q board. :
Why is my latch not retracting when I depress the push pad on an XP98/99 device?
Resolution:
Pushing on the push bar or activating the EL/QEL or the trim on Von Duprin XP98/99 exit device does not retract the latch, it releases the latch only. Door must be pushed or pulled when device o...: