lever locks for fire doors

RELATED FAQS

Question
Answer
Check the timing first, Where can I find timing instructions for the Falcon T lock? The keyspindle assembly for the T/RU571 and the T/RU561 was re...
Replace the lock chassis as necessary for any T locks exhibiting this issue.  RU locks need to be replaced entirely. 
The AD and CO locks both have a 3 hour fire door rating. Please see URL for more info.  UL Fire Rating List
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...
This change was implemented in firmware package CO.A.6 (or later) to help the customer in the communication and coupling process between the CO200 (CO250) and the hand held device (HHD). ...
The green LED is to be lit up until the spindle (Triangles and Key Switch) are aligned properly; providing a visual indication of the problem.  
If the mechanical alignment of the triangles on the back of the outside escutcheon are not aligned, the CO200 or CO250 will not connect with the SUS/HHD and will appear to be unresponsive...
In firmware CO.A.6 (or later) the Schlage button on the CO200 (CO250) will turn green anytime that the spindle triangles on the front escutcheon are out of alignment or the mechanical key switch is...
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into a standard 4 ...
The AL and ND locks are not available in any stainless steel finishes.  The only option is either the 626 satin chrome or 625 bright chrome.
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 1/2" ID steel conduit through the...
Interconnected Locks: a lockset whose trim provides a means of simultaneous retraction of two or more bolts which may also be operated independently Medium duty Commercial, government or multi-...
The 20 minute Fire Rating is a valid label and are commonly referred to as "Smoke and Draft control door assemblies". Depending on the local fire code and the openings's applica...
Cylindrical Locks: a bored lockset whose latch or bolt locking mechanism is contained in the portion installed through the cross-bore Medium, high to extra heavy duty Commercial, multi-family a...
The following common wiring diagrams are available:One Single Door with Panic BarElectric Latch Retraction, with Auto OperatorDelayed egress - Fire Rated ApplicationAuto Operator and actuatorElectr...
Electronic Protocols:Access Control Door with electric trimAccess Control with electric strike Access control with electric strike and LCN 4600 automatic operatorAccess Control with remote Loc...
For W lock levers, you can choose whether or not to install the mounting posts.  This will also affect how the door is prepped so be sure to determine how you will install the locks befor...
Falcon manufactured an EZF101 which was a large plate with a recessed lever for use in elevators.  This item is no longer available.     
The square block is probably the springcage assembly, L283-040.  This component has an internal spring to keep the lever in the horizontal position.