Question
Answer
Can the 6111 electric strike be used with Falcon 25R?
Resolution:
For the backset see the Falcon (F)25-R template; T-1201 for Metal Door, W-1201 for Wood Door. For Single Doors, the distance from the surface of the raised stop to the Centerline of the device is...:
Does the 8827 with the 248L-4 strike meet ADA?
Resolution:
The 248L-4 strike will not violate ADA. If you change the 248L-4 to the 304L strike, then the latch would need to be lowered.:
What mullions should be used with XP devices?
Resolution:
The Von Duprin XP98/99 device uses a different strike than standard 98/99 device. The 909 strike is for non fire rated XP devices and the 954 strike is for the fire rated XP device. 49/9954 mul...:
Is the device centerline of the 9975, the same as the centerline of the 6223 strike?
Resolution:
The centerline of 6223 is the same as the centerline of the mortise latch bolt. So the centerline of the mortise latch bolt or center line of the 6223 is 15/32" above the centerline of the device.:
Is the 2126A bottom strike still available?
Resolution:
The 2126A strike was discontinued in 2009.:
What electric strike can be used with the 1790?
Resolution:
None of the Von Duprin electric strikes will work in a retrofit application where the normal standard mechanical strike is mounted to the frame because none of them are thin enough to fit in...:
Is there a monitor switch for the 6300 electric strike?
Resolution:
There are no optional monitor switches available for the 6300 electric strike.:
Are the 6000 series strikes field selectable for 12 or 24 VDC?
Resolution:
All 6000 series electric strike would require the solenoid be replaced to convert from one voltage to the other.:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
TOP STRIKE
Resolution:
299, 299F, 499F, 338:
What is the minimum dimension from the edge of the door to a glass light cutout?
Resolution:
Minimum dimensions to cutouts for glass lights: Vertical edge of door to edge of cutout = 5 29/32" Top of door to top of cutout = 6" Bottom of door to bottom of cutout = 10" Reinforcing chann...:
Can the 9927 exit device be installed Less Top Rod?
Resolution:
The top rod is required for proper operation. The top latch controls both the top & bottom rods and without the top latch/rod the bottom latch would release when pushpad or trim was used but then ...:
What is the part number for 98/9927-F top latch less cover?
Resolution:
The part number for 98/9927/F top latch less cover is 050400.:
Can a 4640 operator be mounted on a Flush Ceiling application?
Resolution:
4640 Flush Ceiling mounting requires a minimum 1-3/4" Header, and a minimum 3-3/4" Top Rail on the door.:
How close can the top hinge be to the top of the door?
Resolution:
The minimum top and bottom butt hinge locations are as follows: To the hinge centerline: 4 1/2" and 5" hinges = 5 3/8" is the minimum location from top of door to centerline of the first hi...:
What is the minimum top rail required on a door for 1461 Rw/PA?
Resolution:
The 1461 Rw/PA requires a 4-3/8" minimum top rail on the door without the use of a drop plate. If top rail is less than 4-3/8" a 1460-18PA drop plate will have to be used.:
What is the minimum top rail needed for the 4111 EDA/HEDA?
Resolution:
The minimum top rail required to mount a 4110 closer is 5-1/8" measured from the stop of the frame. If the top rail is less than 5-1/8" the 4110-18 drop plate is required.:
What different types of door coordinators are available?
Resolution:
There are 2 types of door coordinators available: Bar Coordinators (Ives COR Series): Surface mounted to the bottom surface of the frame soffit. The active door lever, located nearest to th...:
Can 576A or 576B strikes be used on wood doors?
Resolution:
The 576A or 576B strikes can be used on wood doors but you should check with door manufacturer if it is a fire-rated door to make sure there are no conflicts.:
How many anchors are in a frame?
Resolution:
For Steelcraft frame anchor locations refer to the frame "Anchoring Systems" section of Steelcraft's Tech Data Manual. Basic guidelines are as follows: Anchor ...:
Can you use a 5547 with an electric strike?
Resolution:
The 5547 device can be ordered with an ES prefix to work in conjunction with an electric strike. This requires LBR and can only be done on non-fire rated applications. To convert an existing ...:
How to adjust the 9847/9947 or 9848/9948 rod adjustment?
Resolution:
See the link to a video instruction, Concealed Vertical Rod Exit Device Adjustment.Manual steps:Open door and release top latch bolt by inserting a screw driver in the hole at the top of the d...:
What is the difference between LR and PL latches on Von Duprin 8827 exit devices?
Resolution:
ES (electric strike) latch is only used with the 8827 less bottom rod on a non fire rated exit device with a 6111 electric strike.:
Will the 9100 series Benchmark III power an electric strike?
Resolution:
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...: