Closers mounted according to LCN installation instructions require no periodic maintenance or seasonal adjustments. Monthly, quarterly, and annual visual inspections are recommended for Fire/...
Because of the new extended LCN warranties and the desire to be consistent across the entire Allegion premium brands, LCN will be moving away from offering an out-of-warranty repair service beginni...
There are a few things that can cause a closer to slam.
The closer could be adjusted incorrectly. Turn all regulating screws clockwise until they stop. Then open each valve 1 and 1/2 turns. If t...
The old 4030 series was:
Handed
Mounted regular arm hinge side.
Had sized springs, were not adjustable.
The 4033 is an obsolete closer. If required, handing can be verified by looking at ...
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature.
De...
Make sure that the hold open nut is not on upside down. The orientation of the hold open nut depends on the mounting.
On a Top Jamb "Push Side" mount, the hold open nut would poi...
How to: What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment. All closers with a "Delay" feature ...