Question
Answer
What doors are available with monorail preps?
Resolution:
Monorail cutouts are only available for non fire rated applications.:
What is the part number for a L mortise lock spindle?
Resolution:
The Schlage L-Series mortise lock spindle and spring part number can be found in the Table 1. Spindles and Springs Part Number Description L283-060 Spindle and spring, 1...:
What are the maximum door width and height sizes?
Resolution:
Maximum nominal (overall) single door sizes are as follows:L-Series (Laminated Door)20 Gage = 3’ 0” wide X 8’ 0” high18 Gage = 4’ 0” wide X 10’ 0” high16 Gage = 4’ 0” wide X 10’ 0” high1...:
What parts are needed to install an L lock on an 1 3/8" door?
Resolution:
The standard L9000 lock can be ordered for thin doors (1 3/8") and the appropriate parts will be shipped. The LV9000, L400, LM9000, Anti-Ligature, and N escutcheon trims a...:
Factory installed louvers?
Resolution:
Stamped louvers are no longer available from Steelcraft in any door series. Steelcraft discontinued this offering in 2008. Steelcraft will only provide a cutout only in doors for louvers.:
Does the SL-Series door have a square edge?
Resolution:
The SL-Series door is a square edge non-handed door. A Hinge Filler (also referred to as Hinge Spacer) is the small removable trim part located on the door between hinge leaf and hinge reinforcem...:
How thick is the 09-611 indicator?
Resolution:
The pricebook suggests (for a 1-3/4" door) using a 1-3/8" cylinder when installing with an 09-611 occupancy indicator.:
Can doors be prepared for raceways in the factory?
Resolution:
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 3/4" ID steel...:
What is the max rating available on an full glass (FG) door?
Resolution:
A UL 20 minute fire rating is the maximum fire rating for a Full Glass (FG) door design. A14-Series door construction: Max fire rating is 20 minute. UL label only FG must use Over-Lapping Stee...:
What is the difference between the L-Series and H-Series doors?
Resolution:
The L-Series doors are designed for virtually all construction requirements in commercial building applications. They have also been tested and approved for uniform wind load per ASTM E330. ...: