Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
l lock metal door
”
RELATED FAQS
Question
Answer
Where are hardware templates?
Resolution:
All the templates can be found at us.allegion.com Please click here :
Are parts still available for the Schlage interconnect G series lock?
Resolution:
The current interconnect lock, S200 series (available in levers only), will not fit into the same door preparation.:
Where can I find hurricane ratings for Schlage and Falcon?
Resolution:
There are several Schlage and/or Falcon locks that have been tested and approved for this application. For Commercial use the locks have been tested and approved as ...:
Can the 5100 electric strike be used with a mortise exit device?
Resolution:
The 5100 electric strikes are for use with cylindrical locks only. Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...:
What is the 022558-000-70?
Resolution:
DISCONTINUED: The Falcon T lock had a reinforcement kit for a 1 3/4" thick hollow metal door that prevents lateral movement of the latch. It is a piece of hard foam shaped like a doughnut...:
What is thermal bow?
Resolution:
Thermal Bow is a temporary condition which occurs in metal doors mainly due to the temperature differential from one side of the door to the other. This may occur in exterior doors when direct sun ...:
What parts are needed to install an L lock on an 1 3/8" door?
Resolution:
The standard L9000 lock can be ordered for thin doors (1 3/8") and the appropriate parts will be shipped. The LV9000, L400, LM9000, Anti-Ligature, and N escutcheon trims a...:
What is the square block that holds the L lock levers onto the door?
Resolution:
The square block is probably the springcage assembly, L283-040. This component has an internal spring to keep the lever in the horizontal position.:
What is the ANSI A115.1 Government 86 Door Prep for the L9000 lock?
Resolution:
See image, ANSI A115.1 Mortise Lock Prep This door prep requires the N escutcheon with the L283-029 spacer kit to keep the springcage from falling into the door.&nbs...:
What is the part number for a L mortise lock spindle?
Resolution:
The Schlage L-Series mortise lock spindle and spring part number can be found in the Table 1. Spindles and Springs Part Number Description L283-060 Spindle and spring, 1...:
Where can I find discontinued G lock templates?
Resolution:
Schlage G Series template locate here. :
Why is the L0170 not available in the L escutcheon design?
Resolution:
The Schlage L0170 is not available with the L escutcheon design because due to the narrow size you cannot fit the mounting plate underneath. The mounting plate must sit on a "diamon...: