Non fire rated doors can be furnished with a maximum 3" diameter hole for viewer preparations.
Fire rated doors have a 3/4" maximum holes size unless otherwise listed by UL or ITS/WHI. Viewers mus...
FM Global is an independent underwriting agency with listing, in-plant inspection, and labeling capabilities.
FM fire rated doors and frames are available, however there are a minimal amount ...
Elevation frames are available in:
F-Series (F16 or F14)
FN-Series (FN16 or FN14)
MU-Series (MU16, MU14)
Additional parameters of the frame components:
Perimeter (Head and Jambs) Frame:
...
F-Series frames are available without returns:
Fire Rated frames must have welded corners.
Frames must include weled in wood or steel stud anchors.
Installation requirements:
...
The UL fire label is only applied to the device center case cover at the factory when the device is built. This label can not be sold or replaced with a new one.
996L trim is a standard Classroom Function lever set for the 98/99 panic devices. The 996L-NL trim is a rigid lever for the 98/99 device where the key will retract the latch on the panic device bu...
Yes, for Panic devices only by ordering the top rod kit part #050574, bottom rod kit part #050575, and screw pack #090061.
Fire Rated devices can NOT be converted and would require a compl...
The 3130 Series closer is UL listed- Fire Rated (UL-10C) for up to 3 Hr.
The Door and Frame Manufacturer needs to be contacted to verify their Door/Frame rating would not be ...
The 25 series devices was designed to replace the 18 series & will completely cover existing door prep from a 18 series device. However, some door re-prep is required for the current 25 de...
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device.
L, B, CE, T and CE-Series doors are available factory prepared
Door...
Maximum UL Fire Rated door sizes are as follows:
A-Series:
4' 0" X 8' 0" single door
8' 0" X 8' 0” double door or pairs
B-Series
4' 0" X 10' 0" single door
8' 0" X 10' 0” double doo...
The SED/MED series closers where discontinued in 2000. The SE or ME series from LCN can be used as replacements to provide a hold open feature, but will not have the smoke detector...
Fire Rated three (3) frames are available in the following maximum door opening sizes:
F and FN-Series frame:
4' 0" X 10' 0" single door opening
8' 0" X 10' 0” double door opening
MU-Ser...
The U-Factor, R-Value and K-Thermal Rating are measurements of thermal transmission through building products.
U-Factor: Overall co-efficient of heat transmission passage through a built-up panel...