Is there an anti ligature exit device
”
RELATED FAQS
Question
Answer
What would cause the Von Duprin 88 series exit device latchbolt not to extend and the crossbar to droop?
Resolution:
The spring in the hinge case or end case assembly lifts the crossbar and both lever arms. If broken, the crossbar and lever arms will drop down. The weight of the crossbar and levers will automati...:
Will the new Von Duprin 33A/35A center case work on old 33/35 series exit devices?
Resolution:
The new 33A/35A center case will not work with the old 33/35 series exit devices. It is never intended to use parts to convert a device from one Series to another Series as this w...:
Do we offer a lever trim with squared top and bottom for the 98/99 series exit devices?
Resolution:
The Von Duprin 994L series trims were square on top and bottom. They were discontinued in July 2010.:
What is the part number for a hex dogging shaft for Falcon Dor-o-Matic 1690 or 1790 exit device?
Resolution:
The part number for 1690/1790 hex dogging shaft is shaft.101:
Can the Falcon Monarch 718C or 718NL trim be used with the 25-C exit device?
Resolution:
The Falcon Monarch 718C and the 718NL trims can be used on the 25-C exit device. The 718C trim is listed in the Price Book for the 25 series The instructions attache...:
Can the CD and EL options be provided on the same 98/99 rim or vertical rod exit device?
Resolution:
There is not enough room for both Cylinder Dogging (CD) and Electric Latch Retraction (EL or QEL) options because they both try to occupy the same space in the device.The dogging mechanism for cyli...:
Can the CD cylinder dogging and RX switch be ordered with 33/35 or 98/99 exit device?
Resolution:
This can be done ONLY with non fire rated exit devices.:
Where do I install my Auxiliary Fire Latch (AFL) in a Less Bottom Rod, Fire Rated (LBR-F) exit device?
Resolution:
Installation should be 6" from bottom of the door. See attached templates as reference. T-5494 for HM Doors W-5494 for Wood Doors:
What would keep the vertical rod exit devices top latch from being held retracted in the open position?
Resolution: