Question
Answer
Are the Von Duprin 6000 series electric strikes rated for continuous duty?
Resolution:
All of Von Duprin 6000 series electric strikes have continuous duty solenoids either 12 or 24VDC.:
Isonas RC03 with Intermittent Connection / Drop
Resolution:
If RC-03 Classics, set the port speed to 10mb / half-duplex, disable autonegotiate. If RC-03 Coldfire, set the port speed to 10mb / full-duplex, disable autonegotiate. Also. these devices...:
What would cause a 4600 Series operator to open up and intermittently stick open?
Resolution:
If manually it opens and closes fine, check to make sure one of the actuators is not getting stuck in the on position. Verify that the "Operating Indicator" LED's -- "POWER and SAFETY CLEAR" LED's ...:
How hot do the 6000 electric strikes get?
Resolution:
If the solenoid of the 6000 series electric strike is powered continuously with proper voltage at room temperature, the solenoid can feel very warm to the touch. Ensure the power supply ...:
Can doors be prepared for raceways in the factory?
Resolution: