Answer
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height:  Quantity  Nominal Frame Height     2     1'...
For both DW and K-Series Drywall Slip-on frames, Steelcraft locates the compression anchor in the jamb soffits approximately 4" down from the head on each jamb. Regardless of door opening height: ...
Steelcraft offers two optional types of reinforcements for open section header to be installed in distributor shop or in the field: Full profile sleeve; is a 14 gauge, 16" long part to fit the p...
The 4110 series closer is installed on a flush transom frame using the -419 flush panel adapter.
Yes, a filler plate can be used to cover an EPT prep as long as it is made from the same material as the frame. This information can also be found in NFPA 80 under Chapter 5 for Field Modifications.
Industry standards for hollow metal frames installation tolerances have been developed by both the SDI (Steel Door Institute) and HMMA (Hollow Metal Manufacturers). Both standards are based on the ...
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documentsClick here to get the updated link to the Steelcraft Shop M...
The rough opening dimensions are the same for either Welded (SUA) or Knock Down (KD) frames For F, FN, FE, DE, MU three sided frames and four sided borrowed light frames: New masonry Walls: N...
 For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening height ...
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device. L, B, CE, T and CE-Series doors are available factory prepared Door...