hold open switch
”
RELATED FAQS
Question
Answer
What does B80 or B140 indicate on an ME closer?
Resolution:
The "B" means "Bypass". The "80 or 140" is the degree of door opening from the fully closed position. "B80" means the hold open feature is bypassed (will not hold open) until the door is opened...:
How to adjust a 4010 hold open arm?
Resolution:
The correct method (process) for setting the hold open is: The 4010 hold open arms are handed, verify correct hand arm. (R or L stamped on main arm) Loosen the hold open nut. Opened the door ...:
Can you manually pull a 4040SE out of hold open?
Resolution:
The holding force on an SE/ME Series door closer is approximately 35 lbs. and they can be manually pulled out of hold open with approximately 35 lbs of force. :
What would cause a 4111 HEDA to not hold open?
Resolution:
The correct method (process) for setting the hold open is: The 4110 HEDA arms are handed, verify correct hand arm. (RH or LH stamped on shoe bracket) Loosen the hold open nut at shoe bracket. ...:
Where does the hold open switch on the 4630 / 4640 wire into on the 1-24 single terminal strip?
Resolution:
The 4600 hold open switch (for the new 1-24 single terminal strip I/O board) wires into terminals 2 and 6 or 4 and 6.:
Why would a 8310-806K be used in conjunction with a 4600 that has a on/off hold open switch?
Resolution:
For wiring diagram see here. :
What is the part # for the 4040 regular arm?
Resolution:
The 4040 regular and hold open arms are different. You would have to get a different arm to convert from regular arm to a hold open function. 4040-3077 for a regular arm. 4040-3077L for a long ...:
What is the minimum door opening width for mounting the 4640 or 4630 on a double door?
Resolution:
The minimum door opening width (for mounting a pair of 4640 or 4630 operators on a double door) is 72" wide (2 - 36" door leaves). Mounting the 4640 or 4630 on a double door that is less than 72" w...:
Can you mount a 4041 Cush arm with a EDA arm template and get 180 degrees opening?
Resolution:
The dead stop post would need to be removed and the 4040/4040XP EDA mounting template for 180° would be followed.:
What is a 85445-900?
Resolution:
The 710095-00 (85445-900) and 84570-900 are the older Sr. Swing analog (non-digital) control. It is replaced by the current Sr. Swing digital control box. If you need to replace an old ...:
In what direction should the hold open nut be pointing for a 4041 H closer, up or down?
Resolution:
Make sure that the hold open nut is not on upside down. The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...:
How do I wire an EL device to normally hold open the latch and release it during a fire alarm?
Resolution:
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted. During a fire alarm, the contact will open, dropping...:
What could cause the Von Duprin EL solenoid not to hold when mechanism cover plate is slide over the solenoid?
Resolution:
If mechanism cover plate causes the EL solenoid to drop when slid over the solenoid, the solenoid plunger requires adjustment. You must lengthen the rod by turning the hex nut in front of the plun...:
When did we start shipping the Senior Swing, Benchmark, and Falcon operators with the ES Filter?
Resolution:
On the Benchmark, if there is line noise from a strike then the unit will lose it's hold open time. Adding the ES Filter, which is a diode, will resolve this issue and the unit will hold it's...: