high wind requirements for doors
”
RELATED FAQS
Question
Answer
Which closer should I use for a "High Wind" condition?
Resolution:
A 4110 with AVB (advance variable back check) would be recommended. Using a SCUSH (Spring Cush) arm will also help minimize shock to all door hardware.:
The Von Duprin 98 or 99 ALK kit will not sound the horn
Resolution:
Followings are the reason for 98/99 exit alarm ALK not sound when push bar is activated. Make sure key switch on exit alarm ALK is turned on, wait for 20 seconds before you activating the pushba...:
Do Steelcraft PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements?
Resolution:
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC 500...:
Are glass lights available in the H-Series door?
Resolution:
Steelcraft offers all the standard lights as well as special size glass lights in the H-series door. Effective April 1, 2012, (Bulletin # B-100.12) the default for Dezigner Trim in H-Series D...:
Can H-Series doors be used in tornado applications?
Resolution:
No. The Steelcraft H-Series hurricane door does not meet the FEMA 361 guidelines. The Paladin (PW14-Series) door does meet the FEMA 361 guidelines.:
Will a 4640 operator open the door in windy conditions?
Resolution:
The 4600 operator is designed to meet the ANSI Code 156.19 that limits the opening force to a 15 lbs. By code and design, the operator must stop opening the door when an obstruction or resistance ...:
What door meets FBC / NOA Zone 4 requirements?
Resolution:
H-Series doors in single leaf applications with only mortise locks meet the FBC / NOA Zone 4 requirements?3070 max flushOutswing & Inswing applicationsZone 4 requires 120 to 170 psf.:
What is clear opening width?
Resolution:
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb. &nbs...:
What is the minimum top rail required on a door for 1461 Rw/PA?
Resolution:
The 1461 Rw/PA requires a 4-3/8" minimum top rail on the door without the use of a drop plate. If top rail is less than 4-3/8" a 1460-18PA drop plate will have to be used.:
Can I order a "one piece" top rod for an 8827 for a 9' door?
Resolution:
8827 vertical rod device is available for 7 or 8 feet tall door standard. 12", 24", 36" and 48" extension rod kits are available for taller doors (8 feet max on fire rated openings). We do no...:
Can a 4640 operator be mounted on a Flush Ceiling application?
Resolution:
4640 Flush Ceiling mounting requires a minimum 1-3/4" Header, and a minimum 3-3/4" Top Rail on the door.:
What is the minimum top rail needed for the 4111 EDA/HEDA?
Resolution:
The minimum top rail required to mount a 4110 closer is 5-1/8" measured from the stop of the frame. If the top rail is less than 5-1/8" the 4110-18 drop plate is required.:
What can be done for a door that will not close against wind pressure?
Resolution:
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...:
When are Panic Devices required?
Resolution:
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...:
Does Von Duprin offer an exit device for exterior use?
Resolution:
Most Panic devices are not designed for exterior applications. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish an...:
What drains the AA batteries on an CO-Series lock?
Resolution:
Causes for AA battery drain in CO-Series LOCKS - Possible Cause Fix/Corrective Actions One of the four AA batteries was inserted reversed and the reserved battery drains the other batteries. ...:
What is the ICC-500 standard?
Resolution:
Only the Schlage LM/LMV9300 series when used with a Steelcraft Paladin door meets the FEMA 320 / 361 guidelines and the ICC-500 standard for wind and impact.:
What drains the AA batteries on an AD-Series lock?
Resolution:
Causes for AA battery drain in AD-Series LOCKS Possible Cause Fix/Corrective Action 1) One the four (or eight) AA was inserted reversed and the rese...: