Question
Answer
Where are hardware templates?
Resolution:
All the templates can be found at us.allegion.com Please click here :
What special template (ST) is used with a 4110 closer and GJ90 series?
Resolution:
ST-2730 is used with a 4110EDA closer and GJ901-904 overhead stop.This can only be used with GJ901-904.If a drop plate is required, a 4010-18 drop plate would be used (A 4110-18 drop plate can not ...:
Can I mount an LCN Cush closer with an GJ overhead stop?
Resolution:
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.:
Does a SEH require a door closer?
Resolution:
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...:
Can a 4110 EDA and a Glynn Johnson 100 be used together?
Resolution:
A special template is not needed, the closer drops down far enough on the door where it does not conflict with the GJ100 series concealed overhead stop. :
Can a magnet, or sentronic device, be released and close the door from a button at a desk?
Resolution:
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wiri...:
What is the mounting difference between a 2010 closer and a 2030 closer?
Resolution:
The 2010 and 2030 closer are not the same. The 2010 Series closer uses the (larger) 4010 cylinder which requires a 4" minimum frame tube to mount in. The 2030 uses the (narrow) "Pacer" cylinder...: