Question
Answer
Is there a left hand hold open clip (block) for a 3130 series closer?
Resolution:
As of Feb. 8th, 2016- LCN launched a new HO feature (block) for all track closers, which is not handed. Part # for the Hold Open clip (block) is 3130-3054 and it also requires the...:
Will CX re-arm if door is held open?
Resolution:
If a door position switch (DPS) is connected across the green and white wires of the old CX (green and red of new CX) the CX would go into alarm if the door is held open when it attempts to rearm.&...:
What do I need to do to make my 4041 Reg/PA a hold open arm?
Resolution:
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...:
Can you replace a regular arm with a hold open with out moving the door closer?
Resolution:
Yes, as long as you stay with the like style arm. Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.:
In what direction should the hold open nut be pointing for a 4041 H closer, up or down?
Resolution:
Make sure that the hold open nut is not on upside down. The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...:
How do you order a 4110 hold open spring cush arm only?
Resolution:
The 4110 hold open spring Cush (Spring H Cush) arm part number is 4110-3049SCNS.:
SPRING HOLD-OPEN CUSH ARM
Resolution:
SHCUSH,:
HOLD-OPEN LONG ARM
Resolution:
HLONG, Deep Reveals:
HOLD-OPEN ARM
Resolution:
H, Hold open arm:
What is the part # for the 4040 regular arm?
Resolution:
The 4040 regular and hold open arms are different. You would have to get a different arm to convert from regular arm to a hold open function. 4040-3077 for a regular arm. 4040-3077L for a long ...:
How do I set the hold open on my 4040 closer?
Resolution:
The hold open position on a "REG" or "EDA" hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...:
How to adjust a 4010 hold open arm?
Resolution:
The correct method (process) for setting the hold open is: The 4010 hold open arms are handed, verify correct hand arm. (R or L stamped on main arm) Loosen the hold open nut. Opened the door ...:
Will a 4040SE open and hold at 180°?
Resolution:
No, LCN does not have an electronic hold open closer (SE/ME Series) that will provide a solid 180° hold open position. The 3130SE has an adjustable hold open position from 85° to 110° maximum. ...:
What are the 1460 closer arm options?
Resolution:
The 1460 Regular Arm part numbers are: Regular Arm -- 1460-3077 or 1460-3077L for long arm (must specify finish). Regular Arm with PA -- 1460-3077PA (must specify finish). Regular Hold Open Ar...:
What is the part # for the 4040 HCush arm?
Resolution:
The part number for the 4041/4040XP HCush arm is 4040XP-3049CNS.:
When did the 4111 Cush arms become non-handed?
Resolution:
This engineering change did affect the templating of the closer. The stop in the shoe is slightly larger than the original handed cush shoe. The new non-handed arm template locates the closer and s...:
HEDAW/62G
Resolution:
Hold Open Extra Duty Arm w/ Thick Hub Shoe, Hold Open Extra Duty Arm with Thick Hub Shoe, Thick Hub Shoe:
Why would a 4600 not open a full 90 degrees?
Resolution:
A 4600 (4630/4640) not opening to a full 90 degrees could be caused by a couple things: The Opening Force could be set too low. Try increasing the opening force adjustment on the controller a 1/...:
HEDAW/145
Resolution:
Hold Open Extra Duty Arm w/ Flush Transom Shoe, Hold Open Extra Duty Arm with Flush Transom Shoe, Flush Transom Shoe:
Can you mount a 4041 Cush arm with a EDA arm template and get 180 degrees opening?
Resolution:
The dead stop post would need to be removed and the 4040/4040XP EDA mounting template for 180° would be followed.:
HW/PA
Resolution:
Hold Open Arm with Parallel Arm Shoe:
What would cause a 4111 HEDA to not hold open?
Resolution:
The correct method (process) for setting the hold open is: The 4110 HEDA arms are handed, verify correct hand arm. (RH or LH stamped on shoe bracket) Loosen the hold open nut at shoe bracket. ...:
HLONG
Resolution:
Hold Open Long Arm: