Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
flush bolt on al doors
”
RELATED FAQS
Question
Answer
What strike do I use with a Von Duprin rim device on a pair of doors with flush bolts?
Resolution:
NON Fire Rated doors would use the 1609 strike applied to the inactive leaf with flushbolts. This may NOT be used on Fire Rated openings.:
Are flush bolts available on the inactive leaf of hurricane double doors with either FBC or NOA approvals?
Resolution:
Ives SB360 surface bolt at top and bottom are the only flush bolts approved for use on H-Series hurricane FBC or NOA applications? The only approved latching hardware for inactive leaf of pairs w...:
Does Ives offer a 296G Flush Bolt?
Resolution:
The 296G is is not a model number but rather the UL listing number. This listing would be on many Ives Flush Bolts including; FB30 and FB40 series Automatic Flush Bolts FB50 and FB60 ...:
Can a 4640 operator be mounted on a Flush Ceiling application?
Resolution:
4640 Flush Ceiling mounting requires a minimum 1-3/4" Header, and a minimum 3-3/4" Top Rail on the door.:
FLUSH BOLT BACKSET
Resolution:
Backset:
FLUSH DOOR
Resolution:
F, No glass; Full Flush:
When using a 9927 and you have a flush transom above is there a bracket to mount the latches to?
Resolution:
When using 98/9927 with flush transom above: You will need to use a 260U strike for flush transom applications OR a 260U-F strike for 98/9927-F fire rated device.:
What are the dimensions of the SC70 footprint
Resolution:
The measurements from center line to centerline of the mounting holes are 2-3/8" x 6-3/4".:
Do any products offered by Steelcraft contain asbestos?
Resolution:
Steelcraft doors and/or frames do not contain any asbestos. Steelcraft did use asbestos in the following products: Steelcraft S16-Series stile and rail door with flush panel and UL fire door l...:
What is the Falcon SZ-Series Door?
Resolution:
Falcon SZ Series Door is the economy Steelcraft commercial grade door recommended light commercial applications when architectural specification are not needed. Options: The SZ-Series door is...:
What causes the top latch of a 1690 to not hold in the retracted position while the door swings?
Resolution:
The top rod is adjusted too short, so when pushpad is pressed it is not operating the top latch enough to get into the hold down position. The top rod would need to be lengthened by turning the lat...:
Explain the B580 deadbolt function.
Resolution:
The B580 "Door Bolt" is a deadbolt that is thrown or retracted by the inside turn unit only. There is no outside trim or keyed cylinder.: