Question
Answer
How to adjust the 9847/9947 or 9848/9948 rod adjustment?
Resolution:
See the link to a video instruction, Concealed Vertical Rod Exit Device Adjustment.Manual steps:Open door and release top latch bolt by inserting a screw driver in the hole at the top of the d...:
Will the 6210 work with the Best 45H? If not is there another electric strike that is compatible.
Resolution:
***The 6210 electric strike was designed to replace mechanical strikes in existing openings when access control is desired.*** Note: The Best 40H series lock is not listed on the 6210 electric s...:
What is the Multi Point LM9300 Series?
Resolution:
MultiPoint locks are three-point locking systems that secure the door at three points – top, bottom, and traditional center latch location. Operating just like traditional locks, MultiPoint locks...:
Can the Von Duprin exit alarm ALK and electric latch retraction QEL or EL device be in the same device?
Resolution:
No, Von Duprin exit alarm ALK and electric latch retraction QEL or EL are installed in the same location and can't be ordered together with the same device.:
Does Von Duprin have a fire latch that will go into the floor?
Resolution:
Auxiliary fire latch is tested only from door to door latching by Von Duprin. Some door manufacturers have tested our devices LBR and use additional fire latches to pass the fire test. Contact the ...:
Is there an indicator rose for the B500 or B600 Series?
Resolution:
This can be done but will require a submission through the RFQ process.The Schlage B500 and B600/700/800 deadbolts have an inside indicator rose option for select functions. The indi...:
What is the standard undersize for Steelcraft transom panels?
Resolution:
Steel transom panels are available: 1 3/4" thick panels - supplied in L-Series (L20, L18 or L16-Series) laminated construction. Recommended down sizing is as follows: Without Transom Bar 3...:
Can you mount a 4040XP CUSH with a Flush Transom frame?
Resolution:
The 4040 XP CUSH/EDA can be mounted on a Flush Transom frame by using a -419 Flush Panel adapter.:
FLUSH BOLT BACKSET
Resolution:
Backset:
When using a 9927 and you have a flush transom above is there a bracket to mount the latches to?
Resolution:
When using 98/9927 with flush transom above: You will need to use a 260U strike for flush transom applications OR a 260U-F strike for 98/9927-F fire rated device.:
Where can I find templates for the 237L two point latch device?
Resolution:
Click HERE for the instruction and template for 237L device.:
What causes the top latch of a 1690 to not hold in the retracted position while the door swings?
Resolution:
The top rod is adjusted too short, so when pushpad is pressed it is not operating the top latch enough to get into the hold down position. The top rod would need to be lengthened by turning the lat...:
Why doesn't full rotation of the AD or CO Series Exit Trim (993) outside lever fully retract the Von Duprin 98/99 Exit Device latch?
Resolution:
- AD Series and CO series products require that the Night Latch (NL) screw is installed in the exit device. Be sure this screw is installed- Exit hardware and strike must be properly mounted ...:
How do you install a 4110 with flush transom frame?
Resolution:
The 4110 series closer is installed on a flush transom frame using the -419 flush panel adapter.:
Can a 4640 operator be mounted on a Flush Ceiling application?
Resolution:
4640 Flush Ceiling mounting requires a minimum 1-3/4" Header, and a minimum 3-3/4" Top Rail on the door.:
What drop plate is used with a 4040 Rw/PA?
Resolution:
The 4040 Rw/PA can be mounted 3 different ways. The 4040-18 drop plate is used for the regular pull side mount. The 4040-18TJ drop plate is used for the top jamb push side mount. The 4040-18P...:
Are astragals required on fire doors?
Resolution:
Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...:
Is there anything special about 2" thick doors for the 98/9947 devices?
Resolution:
Standard 98/9947 works on 1 3/4"- 2 1/4" thick door.:
FLUSH TRANSOM SHOE
Resolution:
PA Installation, PA Mount, Flush Transom:
FLUSH PANEL ADAPTER
Resolution:
Narrow Frame, PA Mount, Parallel Arm Mount, Parallel Arm Installation, PA Installation:
Where is factory recommendation for location of an EPT?
Resolution:
EPT installation guidelines are as follows: Recommended location is 6" below top hinge per template Steelcraft will locate the power transfer prep at the Von Duprin re...:
How close can the top hinge be to the top of the door?
Resolution:
The minimum top and bottom butt hinge locations are as follows: To the hinge centerline: 4 1/2" and 5" hinges = 5 3/8" is the minimum location from top of door to centerline of the first hi...:
What is 5, 10 and equal (NAAMM/HMMA) hinge spacing?
Resolution:
"5, 10 and equal" Hinge Spacing: The industry terminology which usually refers to the Custom (NAAMM/HMMA) Door hinge locations. This location dictates: Top Hinge - located 5" from the underside ...:
How many P & D (Pierce and Dimple) holes are in a frame?
Resolution:
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height: Quantity Nominal Frame Height 2 1'...:
What are the ANSI recommendations for the actuator mounting height and distance between the wall actuator and the door opening?
Resolution:
Always check the most current revision of the ANSI A156.19 standard for recommendation or requirement of the location of a Knowing Act switch. 2019 ANSI A156.19 states the requirement of the ...:
Where is the EPT location of a Pin-and-Barrel Continuous HInge?
Resolution:
The 600/700 Series EPT Template shows recommended locations based on the standard sizes, The customer can provide a different dimension measured from the top of the hinge to the Cen...:
How many anchors are in a frame?
Resolution:
For Steelcraft frame anchor locations refer to the frame "Anchoring Systems" section of Steelcraft's Tech Data Manual. Basic guidelines are as follows: Anchor ...:
What is Steelcraft's standard hinge locations for a 6'8" high frame from head to top of each hinge?
Resolution:
The location to the top of hinge will vary depending on hinge size used. 6'8" Frame with 1 1/2 pair of hinges (top to top): For 4 1/2" hinges from the head to top of each hinge is 7 1/2", 37 7...:
What are the frame hinge locations for a 9'0" door opening?
Resolution:
From Head to top of each 4 1/2" hinge is 7 1/2", 36 51/64", 66 3/32" & 95 25/64". From Head to top of each 5" hinge is 7 1/4", 36 35/64", 65 27/32" & 95 9/64".: