Question
Answer
Are Steelcraft doors and/or frames fire rated?
Resolution:
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...:
What is the rough opening in walls for frame installations?
Resolution:
For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening hei...:
What is ASTM E-119?
Resolution:
ASTM E-119 is a test standard for walls, partitions and floor or roof systems: This test standard is also used for ceramic type glasses when used as window wall and/or borrowed light frames.As...:
Are hospital stops approved on fire rated frames?
Resolution:
Yes, hospital stops are available on fire rated frames. Maximum approval = 3 hour Maximum sizes: singles up to 4'0" x 8'0" pairs up to 8'0" x 8'0" Maximum hospital stop height 6" from bot...:
Are frames available without backbends?
Resolution:
F-Series frames are available without returns: Fire Rated frames must have welded corners. Frames must include weled in wood or steel stud anchors. Installation requirements: ...:
What fire ratings are available on DW-Series Borrowed Lights?
Resolution:
DW-Series Fire Rated Borrowed Lights are available in the following sizes: 60 minute (1 hour) rating = 2721 square inches of visible glass. maximum frame rabbet to rabbet dimensions = 78 1/4...:
What is the maximum size of a UL fire rated three (3) sided frame?
Resolution:
Fire Rated three (3) frames are available in the following maximum door opening sizes: F and FN-Series frame:4' 0" X 10' 0" single door opening8' 0" X 10' 0” double door openingMU-Series frame...:
What is the maximum size of a ITS/WHI fire rated three (3) sided frame?
Resolution:
ITS/WHI Fire Rated three (3) frames are available in the following maximum door opening sizes:F and FN-Series:4' 0" X 10' 0" single door8' 0" X 10' 0” double door or pairsMU-Series:4' 0" X 9' 0" si...:
Can wood doors be used with with double egress frames?
Resolution:
Yes, wood doors can be used and installed in most hollow metal frame applications including FE-Series and DE-Series Double Egress frames. Caution - For fire rated applications the wood door manufa...: