Falcon began offering an RX switch with its electrified functions beginning January 17th 2012.  To specify, add "RX" to the end of the part number. Example:  Storeroom Function, Fail Safe (EL), 12...
The MA RX features independent switches within the chassis that allow the customer to choose whether to monitor the inside or outside knob/lever.
Each switch is pre-wired to work with either normally open or normally closed systems, with color coded 5 ft long leads.
See Marketing announcement here
If the RX switch is in the device itself yes. You can not however have both the "E" and "RX" options in the same 996L trim as both the solenoid & switch are mounted in the same place in the trim.
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.
The RX switch is required to activate the ALK. The RX switch monitors the pushbar and will signal the ALK to go into alarm when the pushbar is depressed. The RX switch also allows free in...
There is not a kit for insulclad applications.  When ordering the device, specify the applied panel size and the door size to get the appropriate hardware. 
The 330 must be ordered as a RX330 to have the RX switch.  You can NOT add a RX to an existing dummy 330 bar.
For the older 17/18 or current 19 device per instructions :  Red - Normally Open  Green - Common   Black - Normally Closed
For 24/25 devices per instructions :   Violet - Normally Open   Black - Common   Gray - Normally Closed
You must replace the entire RX switch assembly for Chexit devices shipped after 8-24-2015 with motor driven.
The part number for the RX switch pig tail (black plug) with two orange wires only for Chexit devices shipped prior to 8-24-2015 with solenoid driven is 991338-00. 
Von Duprin offers two options:The CDSI/HDSI Dogging Indicator provides an at-a-glance verification of the status of the door from inside of the room. Visible “LOCKED” and “UNLOCKED” indicators show...
There is no EL conversion kit for a 2390, the device will need to be replaced.
The devices baseplates/scissor assemblies are different and will not accept the Von Duprin RX switch.
The RX-LC and LX-LC (Low Current) switches are used for current up to 0.05 amps at 24 VDC and the standard RX and LX switches are used for current greater than 0.05 amps up to 0.5 amps at 24 VDC.
Here is detailed information on why the Von Duprin RX-LC Swtich is required by the AD300 and AD400 993 units.   A low current switch is needed because … -     &nb...
The RX switch can be installed at the factory when device is ordered or in the field with part# 650359-00. Installation instructions here will show how the RX swi...
For any device made after 2001, the part number for the Falcon 1690 dogging kit would be KIT.1197 For devices made prior 2001, the dogging kit is no longer available and a new device must be ...
Chexit devices shipped after 8-24-2015 with motor driven:If two pin REX connector cable is plugged into the Chexit module and Module REX LED is OFF, the RX switch is defective and needs to be repla...
Chexit devices shipped prior to 8-24-2015 with solenoid driven:If Chexit device goes into alarm with fast flashing red LED after the rearm time, the RX switch may be out of adjustment or defective....
For Chexit devices with solenoid driven shipped from the factory prior to 8-24-2015, the RX switch is ordered as a "Special CX RX Switch".  It may only be installed or adjusted on ex...
The Falcon T Series lock does not have an RX switch available.
The Exit Alarm takes a 1 1/8" Mortise cylinder with a straight cam. See first page of Exit Alarm inst below. Exit Alarm inst
Yes, part numbers for Falcon electric latch retraction EL conversion kits are as follows: 650147 for a 3' device. 650148 for a 4' device. 
RX wiring on all L9000 locks with RX switch manufactured after January 2, 2017:The L-Series switched to a handed modular three-wire request to exit (RX) switch. This change was originally completed...
Specific to the RX switch installed into the L9080EL/EU and L9082EL/EU and L9000 mechanical locks prior to January 2, 2017:ALL PART NUMBERS BELOW DISCONTINUEDThe L-Series switched to a three-wire r...
RX switch is request exit and LX switch is latch bolt monitor switch. They do not required a power supply directly. The electrified hardware that RX or LX switch conne...
The AE option is now called RX (Request to Exit) to match other Allegion exit brands nomenclature. The feature of getting a signal from the pushing of the device's pushpad is the same.
The ND-Series RX,  the L-Series RX and latch monitoring switches are Form C - Single Pole Double Throw (also known as SPDT).
There is no conversion kit to add EL or ED to an existing 1690 or 1790 series device. All of the components are built into the device, since the device does not have a separate baseplate.&n...
L283-263 and L283-239 are obsolete part numbers that were used to specify "request to exit" on the L9000 and LV9000 locks. To specify RX on L9000 locks after January 2, 2017, specify the lette...
The QEL conversion kit (3' or 4') and the RX switch kit (050251-00) can convert the 9927 to QEL-RX9927 device.
The RX request exit switch is not available with 94/95 exit devices.
Solenoid: Black (2 wires) Case side RX Normally Open: Green Normally Closed: Orange Cover side RX Normally Open: Gray Normally Closed: Red Common: Yellow
Refer to the MA RX diagram here for more information.
The Falcon 1390 exit device is discontinued and parts are no longer available from the factory. New England Door Closer may still have some older kits and can be contact...
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.
This option is not available.  The 17 & 18 Series devices were discontinued in August 2009 and the new Falcon RX Switch is mounted to a bracket that fits in the pushpad...
The RX monitors the push bar while the LX monitors the latch bolt of the exit device. A SS device has an LX and a key cylinder switch plus an emergency push bar signage.
The Von Duprin RX996L trim was released to standard order entry in May 2010. The Von Duprin 996L and 996L-BE trims can be ordered with RX switch. The 996L-NL and 996L-DT trims can not have the...
The Von Duprin RXLX combination switch must be ordered together as one assembly. Existing RX or LX switch must be removed to install the combination RX LX switch. Make sure correct RX LX combinatio...
The hole should be drilled in the field once the end cap is located on the door.  It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...
For motor driven Chexit devices shipped from the factory after 8-24-2015, the RX switch is standard, part number 116717-00.    
For solenoid driven Chexit devices shipped from the factory prior to 8-24-2015, the RX switch is ordered as a "Special CX-RX switch" by SSC or distributors.  The switch may only be installed o...
The ND lock is available with an RX option:When ordering a complete ND lock specify RX when the request to exit (RX) switch is required.The ND80EL, ND80EU, ND96EL, ND96EU, ND12EL, ND12EU electrifie...
Von duprin will supply the 996L and 996L-BE trims with RX switch. Von Duprin will not supply the 996L-NL and 996L-DT trims with RX switch because the switch monitors the lever movement and the leve...
ALK kit comes with standard RX switch. It can be ordered without the RX switch or with LX switch as an option.
The Request for Exit (RX) is available on the 55 and 88 Series Von Duprin devices.The RX switch is installed in the end case of 55 and 88 series exit devices.There is no kit to field install the RX...