Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
Falcon RX kit options?
”
RELATED FAQS
Question
Answer
Is the MA lock available with the RX feature?
Resolution:
The MA RX features a single switch within the chassis that will monitor both the inside and outside knob/lever. The switch is only available as Normally Open (NO).:
What are the Von Duprin part numbers for RX, LX and RX,LX-LC switch kits for field installation?
Resolution:
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.:
Does the Von Duprin ALK require the RX switch to operate?
Resolution:
The RX switch is required to activate the ALK. The RX switch monitors the pushbar and will signal the ALK to go into alarm when the pushbar is depressed. The RX switch also allows free in...:
Is there an insulclad kit for use with the Falcon 24-C device?
Resolution:
There is not a kit for insulclad applications for the Falcon 24C. When ordering the device, specify the applied panel and door thickness to get the appropriate hardware. See notes below. This...:
Is the RX available for the Von Duprin 330 dummy bar?
Resolution:
The 330 must be ordered as a RX330 to have the RX switch. You can NOT add a RX to an existing dummy 330 bar.:
What are the 3 wires on the Falcon AE switch?
Resolution:
For 24/25 devices per instructions : Violet - Normally Open Black - Common Gray - Normally Closed:
Does Von Duprin offer a classroom security option with visual status indication?
Resolution:
Von Duprin offers two options: The CDSI/HDSI Dogging Indicator provides an at-a-glance verification of the status of the door from inside of the room. Visible “LOCKED” and “UNLO...:
Is there an EL conversion kit for the Falcon 2390 exit device?
Resolution:
There is no EL conversion kit for a 2390, the device will need to be replaced.:
Can the Von Duprin RX Switch be installed on an existing Falcon Monarch 19?
Resolution:
The devices baseplates/scissor assemblies are different and will not accept the Von Duprin RX switch.:
What is the difference between an RX switch and an RX-LC (low current) switch?
Resolution:
The standard Von Duprin switches (RX and LX switches in exit devices, and DS dual switches in 6100 and 6200 Electric Strikes) are rated for 0.05A to 2A @ 24 VDC. The low curren...:
Why does the AD300-993 and AD400-993 require Von Duprin RX-LC switch
Resolution:
Here is detailed information on why the Von Duprin RX-LC Swtich is required by the AD300 and AD400 993 units. A low current switch is needed because … - &nb...:
Can you field install a RX switch on the 24/25 device?
Resolution:
The RX switch can be installed at the factory when device is ordered or in the field with part# 650359-00. Installation instructions here will show how the RX swi...:
What is the part number for the dogging assembly for a 1690/1790/2390?
Resolution:
For any device made after 2001, the part number for the Falcon 1690 dogging kit would be KIT.1197 For devices made prior 2001, the dogging kit is no longer available and a new device must be ...:
How to test the RX switch in a Chexit device.
Resolution:
Chexit devices shipped prior to 8-24-2015 with solenoid driven: If Chexit device goes into alarm with fast flashing red LED after the rearm time, the RX switch may be out of adjustment or defect...:
Who can adjust or replace the Chexit RX switch?
Resolution:
For Chexit devices with solenoid driven shipped from the factory prior to 8-24-2015, the RX switch is ordered as a "Special CX RX Switch". It may only be installed or adjusted ...:
Does the Falcon T series have an RX option available?
Resolution:
The Falcon T Series lock does not have an RX switch available.:
What cylinder is used in the Falcon 24/25 exit alarm kit?
Resolution:
The Exit Alarm takes a 1 1/8" Mortise cylinder with a straight cam. See first page of Exit Alarm inst below. Exit Alarm inst:
What power supply is used with RX or LX switches?
Resolution:
The RX switch is request exit and the LX switch is latch bolt monitor switch. They do not require a power supply directly. The electrified hardware that the RX or LX switch...:
Is the RX option the same as the old AE option on Falcon exits?
Resolution:
The AE option is now called RX (Request to Exit) to match other Allegion exit brands nomenclature. The feature of getting a signal from the pushing of the device's pushpad is the same. :
What type of switch is used for the RX and latch monitoring options for the ND and L locks?
Resolution:
The ND-Series RX, the L-Series RX and latch monitoring switches are Form C - Single Pole Double Throw (also known as SPDT).:
Is there a conversion kit to add Electronic Dogging (ED) or Electric Latch Retraction (EL) to a 1690 or 1790 in the field?
Resolution:
There is no conversion kit to add EL or ED to an existing 1690 or 1790 series device. All of the components are built into the device, since the device does not have a separate base...:
What is the L9080 by L283-263?
Resolution:
L283-263 and L283-239 are obsolete part numbers that were used to specify "request to exit" on the L9000 and LV9000 locks. To specify RX on L9000 locks after January 2, 2017, specify the lette...:
Can QEL and RX be added to an existing 9927?
Resolution:
The QEL conversion kit (3' or 4') and the RX switch kit (050251-00) can convert the 9927 to QEL-RX9927 device.:
Can the 94/9547 have the RX option?
Resolution:
The RX request exit switch is not available with 94/95 exit devices.:
Falcon MA lock wire color.
Resolution:
Solenoid: Black (2 wires) RX (monitors both sides) Normally Open: Green (pin 6 when connector included) Common: Orange (pin 5 when connector included) The current version o...:
Is the Falcon 1390 exit device dogging kit (4270106669) still available?
Resolution:
The Falcon 1390 exit device is discontinued and parts are no longer available from the factory. New England Door Closer may still have some older kits and can be contact...:
What is (SD) Special Dogging?
Resolution:
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.:
Do we offer a RX switch for the 17 or 18 device?
Resolution:
This option is not available. The 17 & 18 Series devices were discontinued in August 2009 and the new Falcon RX Switch is mounted to a bracket that fits in the pushpad...:
What is the difference between Von Duprin LX and/or RX switches and the Signal Switch SS option?
Resolution:
The RX monitors the push bar while the LX monitors the latch bolt of the exit device. A SS device has an LX and a key cylinder switch plus an emergency push bar signage.:
When did we Von Duprin release the RX996L trim as a standard?
Resolution:
The Von Duprin RX996L trim was released to standard order entry in May 2010. The Von Duprin 996L and 996L-BE trims can be ordered with RX switch. The 996L-NL and 996L-DT trims can not have the...:
Can you add the LX option to a Von Duprin device that already has the RX option?
Resolution:
The Von Duprin RXLX combination switch must be ordered together as one assembly. Existing RX or LX switch must be removed to install the combination RX LX switch. Make sure correct RX LX combinatio...:
Is there a template that shows where to drill the hole for E/EL/SS/RX/LX/CX wires?
Resolution:
The hole should be drilled in the field once the end cap is located on the door. It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...:
What is the part number for the CX-RX switch?
Resolution:
For solenoid driven Chexit devices shipped from the factory prior to 8-24-2015, the RX switch is no longer available. This part was discontinued in 2019. If the older version Chexit RX s...:
Does the ND lock have an RX option?
Resolution:
The ND lock is available with an RX option: When ordering a complete ND lock specify RX when the request to exit (RX) switch is required. The ND80EL, ND80EU, ND96EL, ND96EU, ND12EL, ND12E...:
Will Von Duprin supply the 996L, 996L-BE, 996L-NL and 996L-DT trims with an RX switch?
Resolution:
Von duprin will supply the 996L and 996L-BE trims with RX switch. Von Duprin will not supply the 996L-NL and 996L-DT trims with RX switch because the switch monitors the lever movement and the leve...:
Does a Von Duprin ALK kit come with an RX switch?
Resolution:
ALK kit comes with standard RX switch. It can be ordered without the RX switch or with LX switch as an option.:
Can a 55 or 88 series device have a request to exit switch?
Resolution:
The Request for Exit (RX) is available on the 55 and 88 Series Von Duprin devices.The RX switch is installed in the end case of 55 and 88 series exit devices.There is no kit to field install the RX...: