falcon monarch warranty

RELATED FAQS

Question
Answer
The devices baseplates/scissor assemblies are different and will not accept the Von Duprin RX switch.
 The Falcon Monarch 718C and the 718NL trims can be used on the 25-C exit device.  The 718C trim is listed in the Price Book for the 25 series  The instructions attache...
See the installation instructions 718 for -C devices.
Templates for current 718 series trim can also be found on Falcon website
The Von Duprin PS914 power supply with either the 900-2RS  or the 900-4RL option board is required.
As of August 3rd, 2011 this is no longer an option.
Yes, "Standard" was the old name for the sectional pull trim for the 18/XX devices and is now called Athena.  The trim is the same, only a name change.
The hex dogging key size for all Falcon-Monarch exit devices is 7/32".
The "904H" is a UL Panic label that is placed on the centercase of the Falcon/Monarch Panic device.
Falcon Monarch 24 series exit devices replaced the 17 Series exit devices. Falcon Monarch 25 series exit devices replaced the 18 Series exit devices.
PCB only for the Alarm Kits prior to June 11th, 2012 is part #650335 and was used in the older 17 & 18 devices, 19, & pre June 2012 24/25's.
This circuit board will NOT work on the updated 24/25 Alarm Kits that released June 11th, 2012.
The current 712L/912L (after 2/28/2011) can be field converted by purchasing the NL Spring part #600339 and following the L to NL function change instructions.
The resistance readings for a Falcon 24 or 25 Series EL solenoid should read;Green to Yellow = Pull Coil, should measure between 1 and 2 ohms of resistance. Green to Orange = Hold Coil, s...
There is not a chart that shows which sex bolts are required for Von Duprin or Falcon/Monarch exit devices.
For Warranty information, visit us.allegion.com/warranty or contact Customer Service at 877-671-7011.