Explain closer preload
”
RELATED FAQS
Question
Answer
What is the amount of pre-load force allowed for the 6300 electric strike before the strike will no longer release and operate properly.
Resolution:
The 6000 series electric strikes 6100, 6200, 6300 models, require that there be no preload at all on the strike lip to function properly.:
Why does the arm of my 4110 EDA touch the door when it is closed?
Resolution:
If the closer arm is touching the door, it is because the arm or the closer body is not templated correctly. Confirm dimensions are taken from the proper location and make corrections if needed. :
What is maximum width, height and weight for IVES butt hinges?
Resolution:
Butt hinges can be used on doors up to 4' wide and 200 pounds. There is no maximum door height. However, an additional hinge must be installed every 30" when exceeding a 7' d...:
What is the load for a 059 and 59 handrail bracket?
Resolution:
250 lbf:
Do we have a maximum door width or height for using pivots?
Resolution:
The maximum door width that pivots have been tested is a 4' wide door. Any door greater than 4' would shorten the life of the pivots. There is no maximum door height, for offset pivots the ru...: