exit devices installation instruction
”
RELATED FAQS
Question
Answer
What are the Von Duprin part numbers for RX, LX and RX,LX-LC switch kits for field installation?
Resolution:
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.:
How is the QEL calibrated?
Resolution:
The QELA motor that has shipped since 2015 is self calibrating. Older versions had a calibration button, and these notes would apply: Calibration is an internal process of the QEL device&...:
Do we have instructions on how to clean an exit device?
Resolution:
Recommendation is to use mild soap with a damp cloth to clean an exit device.:
What is SLM blocking and how does it effect exit device installation?
Resolution:
SLM - special laminated material - blocking is put into the wood doors so there is material to mount the exit device using wood screws.:
Where do I install my Auxiliary Fire Latch (AFL) in a Less Bottom Rod, Fire Rated (LBR-F) exit device?
Resolution:
Installation should be 6" from bottom of the door. See attached templates as reference. T-5494 for HM Doors W-5494 for Wood Doors:
Is there a template that shows where to drill the hole for E/EL/SS/RX/LX/CX wires?
Resolution:
The hole should be drilled in the field once the end cap is located on the door. It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...:
How far down can an exit device be cut down in the field?
Resolution:
For most exit devices, please refer to the specific device series catalog for minimum door opening width the device can be cut down to fit. Be aware that some device options, frame...:
What wire gauge and run is recommended for Von Duprin electric latch retraction EL device?
Resolution:
:
What gauge wire is needed for CX red and black power wires?
Resolution:
For Product Shipped prior to 8-24-2015 with solenoid and EPT or Door Loops: a. 0-100 ft, use #14 Gauge Wire ...: