electric strike with concealed rod

RELATED FAQS

Question
Answer
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...
The DS is Dual Monitor Switch for Von Duprin 6000 series electric strikes. DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only available factory inst...
The Falcon 25R rim device can be used with 6111 electric strike on single or double doors. Additional Information: The Von Duprin 4854/9854 mullion is required when using 25R with 6111 electric...
 For the backset see the Falcon template above, the "B" dimension would be 3-1/4".
The 6216 electric strike was designed only for use with only the Folger Adams 310-3-1 mortise lock with deadbolt. The dead bolt must be retracted manually for the the strike to operate.
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable. To power the 24VDC electric strike or maglock off a LCN Se...
010055-xx is the part number for Blade Stop Shim kit for 6111 or 6113 electric strike and it must be ordered separately.  xx is for the finish callout.
The 6300 surface mounted electric strike can be used with a 22 rim device.
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
Devices built After 2/28/2011: Use a 1 1/8" - 1 1/4" mortise cylinder with straight narrow cam. (Cam profile same as the Schlage B520-731, see table below for part numbers) Devices built Befo...
 Modular 1-1/8"  Modular 1-1/4"  SFIC and FSIC  Non-Modular Non-IC Conventional  Non-Modular Non-IC Everest Primus  B520-730  B520-731  B520-2...
The AD or CO - 993 is NOT compatible with a Von Duprin 98/99 Concealed Vertical Rod exit device on wood doors.
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.
Following parts are required to add the bottom rod and latch to the 98/9927-LBR device.  Bottom Rod: 050515 for 9827 and 050514 for 9927 (specify finish)  Bottom Latch Assembly: 05009...
The Von Duprin 6300 surface mounted electric strike is compatible with 55 rim device.