electric strike vertical rod device
”
RELATED FAQS
Question
Answer
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
What parts are necessary to add the bottom rod/latch/strike to a 98/9927-LBR/LBR-F (less bottom rod) device?
Resolution:
Following parts are required to add the bottom rod and latch to the 98/9927-LBR/LBR-F device. Bottom Rod: 050515 for 9827 and 050514 for 9927 (specify finish) Bottom Latc...:
What strike would be used for a 25-R for pair without mullion?
Resolution:
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.:
Can the CD and EL options be provided on the same 98/99 rim or vertical rod exit device?
Resolution:
There is not enough room for both Cylinder Dogging (CD) and Electric Latch Retraction (EL or QEL) options because they both try to occupy the same space in the device.The dogging mechanism for cyli...:
How do I add the Special Dogging (SD) option to a 98/9927 vertical rod device?
Resolution:
Special Dogging can be added but you will need a new center case assembly, cylinder dog housing, and center case cover. 050550, SD center case kit RHR and 050551, SD center case kit LHR. 112409...: