Question
Answer
Selected the wrong lock model (CO-200 or CO-220) when updating CO Firmware.
Resolution:
For any CO-200-40 Privacy or CO-220-75 Safe School lock that was manufactured before May 2014: When updating the lock's firmware to CO.A.12 or later, SUS will first ask the question βIs this a CO-...:
What is the part number for the wireless communication module, radio board, COM400, with the remote antenna connection (gold jack)?
Resolution:
The COM400 has only two versions of FW, 2.2a and 2,2d and they are cross compatible and completely functional with all AD-Series wireless devices. There is no reason to change a FW 2.2a to a FW 2...:
Why can't I LINK my AD-Series lock?
Resolution:
4. PIM400/AD400 COM400 plug could be damaged! The small pins in the Main PCB board connection for the RF COMM board can get bent during installation of the RF COM400 board. If the PINs are be...:
Which AD firmware package version supports WRI400/CT5000 devices?
Resolution:
SUS 4.4.0 released on 06/06/2011 is the first released SUS version compatible with WRI400 and CT5000 devices.: