Double egress reveal max
”
RELATED FAQS
Question
Answer
What is the maximum size of a UL fire rated three (3) sided frame?
Resolution:
Fire Rated three (3) frames are available in the following maximum door opening sizes: F and FN-Series frame:4' 0" X 10' 0" single door opening8' 0" X 10' 0” double door openingMU-Series frame...:
What is maximum reveal for the 9140?
Resolution:
Reveal should not exceed: 6" for the REGULAR ARM 9 3/4" for the LONG ARM:
Can a 4040XPT DE be used with a 4" reveal on the pull side?
Resolution:
The LCN 4040XPT with a reveal deeper than 1/8" on the pull side of the opening requires a Double Egress (DE) arm.DE arms are handed arms and cannot have handing changed in field.ST3073 Standard 404...:
What is the minimum and maximum reveal for a 9500 Series Senior Swing operator?
Resolution:
The 9542, 9553, 9563 surface mounted Senior Swing with a regular arm, mounted on the push side of the door, can handle a reveal from 1 1/8" up to 10". The 9542, 9553, 9563 surface mounted Senior S...:
Does a SEH require a door closer?
Resolution:
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...:
What is the maximum reveal for a regular arm 4642 operator?
Resolution:
Max. reveal for a 4642: 4640 Regular arm -- 4.5" 4640 Long arm -- 8" 4640 x ST-3088 ( custom made - extra long rod) -- 8" to 11" No special mounting instructions required, just standard templ...:
How deep of a reveal will an 8200 Falcon Operator accommodate?
Resolution:
The maximum reveal for an 8200 Falcon Operator is: 8230 (pull side) -- 1/8" 8240 (push side) -- 6" The Benchmark long rod and shoe (9140-79LR) can be use with the Falcon 8242 for reveal from ...:
Can fire rated double egress frames have side lights or transoms?
Resolution:
No. Fire rated double egress frames must be a stand alone 3 sided frame assembly. If transom lights and/or sidelights are required, they must be built and installed as separate Fire Window assemb...: