Doors keep getting updates
”
RELATED FAQS
Question
Answer
Why do I get error message "E701 - Programming Lock Failed" on my Hand Held Device while programming an AD lockset?
Resolution:
Update your lockset using ADFwPkg 2.19.0 or higher. This new firmware update resolves this programming error problem (E701) and the error will no longer be presented.:
Does a SEH require a door closer?
Resolution:
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...:
When adding a credential or updating a credential I get an error that the No Tour Credentials Are Full.
Resolution:
The No Tour function only allows writing to 11 sectors on the fob. Each lock added to a user uses 1 sector. Once those 11 sectors are full, No Tour is not available. You can still ...:
Why does the Schlage Utility Software application display the error message "E201 - This device is not connected?"
Resolution:
The E201 message can be ignored and all normal SUS and lock functions will be maintained. Click "OK " and continue. Update the Schlage Utility Software (SUS) to version 4.6.0 or highe...:
I get three green blinks of the Schlage key and it says motor stall on my SUS/HHD during diagnostics?
Resolution:
Just align the triangles per the installation instructions to allow full motor movement. - This will eliminate the SUS motor STALL report. - This will eliminate the three ...:
What are the TWO red SCHLAGE flashes on an AD400?
Resolution:
ONE red flash, One red flash indicates RF COM loss, the AD400 radio did not get an answer from the PIM400-485 radio or the PIM400-TD2 radio. The PIM400-485 will turn off it's radio if th...:
How to adjust First, Delay, and Retry in a PIM400 & AD400?
Resolution:
To change FIRST/DELAY/RETRY connect and couple the SUS/HHD to the AD400 and find under the EDIT tab the FIRST/DELAY/RETRY settings. See notes Or connect the SUS/HHD t...:
How do I use an AD-Series Relay Board (RLBD)?
Resolution:
This RLBD data sheet can also be found at Schlage/Technical Support. RLBD DataSheet :
Can I order a "one piece" top rod for an 8827 for a 9' door?
Resolution:
8827 vertical rod device is available for 7 or 8 feet tall door standard. 12", 24", 36" and 48" extension rod kits are available for taller doors (8 feet max on fire rated openings). We do no...: