door frame has rusted

RELATED FAQS

Question
Answer
Excessive premature frame rusting is caused by improper jobsite installation practices and most likely caused by the following circumstances: Grout: Frames are grouted in place using incorrec...
Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...
The following hinges are available on Paladin series doors and frames: Butt hinges -  4 1/2", 5" or 6" ball bearing type either standard or heavy duty Continuous hinges - full mortise...
The backset is 2 3/4" from edge of door to the center line of the device and strike. The preparation for the WS98/99 strike must be specified when placing order for the frame.
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device. L, B, CE, T and CE-Series doors are available factory prepared Door...
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion
When rust appears, repair the affected surfaces by finish smooth, clean, treat for maximum paint adhesion, and touch up the surfaces with a direct to metal (DTM), rust inhibitive primer.
Prime or painted surfaces which have been scratched or otherwise marred during installation (including field welding) and/or cleaning must be field repaired and re-primed by the installing contractor.
CAUTION must be used in investigating this problem - In most cases, excessive field rusting of products is caused by improper storage at the jobsite. That situation must be validated prior to refus...
During the construction cycle, spot rust is usually attributed to either material handling damage or improper storage of the material on the jobsite. The material must be repaired and repainted as ...