Door closer hold open adjustment

RELATED FAQS

Question
Answer
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions.  Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...
 The correct method (process) for setting the hold open is: The 4010 hold open arms are handed, verify correct hand arm. (R or L stamped on main arm) Loosen the hold open nut. Opened the door ...
The hold open position on a "REG" or "EDA"  hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...
120V Models: The hold open force on the 2310ME / 4310ME / 4410ME closers is "NOT" adjustable. 24V Models: There is a trimpot adjustment on the circuit board that allows you to "REDUCE" the hold op...
There are a few things that can cause a closer to slam. The closer could be adjusted incorrectly. Turn all regulating screws clockwise until they stop. Then open each valve 1 and 1/2 turns. If t...
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...
Make sure that the hold open nut is not on upside down.  The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...
Yes, as long as you stay with the like style arm.  Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.