do we have an jamb mounted actuator , that can be installed outside

RELATED FAQS

Question
Answer
To convert a hard wired actuator button to a wireless actuator button you will need the following components: An RF transmitter. The 8310-844 transmitter for the (4-1/2" or 6" round, and the ...
To convert an RF actuator button to a hard wired actuator button, simply remove the RF transmitter an connect the hard wiring to the "Common" and "Normally Open" terminals on the the switch.
The ANSI 156.19 standard states (in appendix A-5 Knowing Act Switches) that wall actuators are to have an installation height of a minimum of 34" and a maximum of 48" (center of the switch) of...
BAA/ARRA stand for Buy American Act and American Recovery and Reinvestment Act. A brief description of some of the federal requirements can be found in the BAA Catalog on the Allegion...
Country of Origin (COO) information can be found in the Buy American Act (BAA) brochure.
To obtain product certification forms:Download the BAA Catalog on the Allegion website Complete the information requested in the the BAA Catalog with a detailed copy of the prod...
 Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted.  Consists of a modified, heavy-duty door closer for manual oper...
The LCN 4041/4040XP and the Glynn Johnson 90 series can be mounted in conjunction with each other without a special template.  The 4040 door closer is on the pull side of the door and the GJ 90 is ...
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.
Maximum reveal for a 4041 regular arm is 2-9/16". The reveal for a 4041 long arm is from 2-9/16" to 4-13/16". The reveal for a 4041 extra long arm (ELR) is from 4-13/16" to 8". ST-2523 is a sp...
This condition (toed in or toed out jambs) is usually not found until the door is installed. Frames which have toed in or toed out jambs have been installed out of tolerance. It is the resp...
The 40401/4040XP closer with optional EDA arm has to be mounted parallel arm on the push side of the door.
The 8310-853 (T) series actuator will mount to either a single or double gang electrical box.
The LCN Bollard post (8310-866) only accepts the "square" actuators (no round actuators). The size of the Bollard post is 4” X 6” X 36”. Acceptable actuator part numbers are: Hard Wired -  831...
EDA ARM - The EDA arm is a heavy duty parallel arm mount.  The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...
For both DW and K-Series Drywall Slip-on frames, Steelcraft locates the compression anchor in the jamb soffits approximately 4" down from the head on each jamb. Regardless of door opening height: ...
Exterior mounting of the 8310-818 series actuators is not recommended. The 8310-818 series actuators are designed to be jamb mounted on the frame. With that installation, the person will have to ...