Question
Answer
What are cycle testing counts for exit devices?
Resolution:
ANSI grade one cycle test is 500,000, grade two is 250,000 and grade three is 100,000.:
Is the AD CO with a 993 chassis compatible with the Von Duprin 33A exit device?
Resolution:
No, the 33A is not compatible with the AD and CO 993 chassis units. The 33A can only be driven in a clockwise direction. This would restrict it to right hand installs only.:
What Von Duprin device works with a Kaba Ilco LP1000?
Resolution:
We do not do testing on other manufacturer's trims to work with Von Duprin exit devices. You will need to contact Kaba Ilco.:
How many times can an EL device be operated when using a PS914-2RS with battery backup?
Resolution:
The Von Duprin PS914-2RS retracts the EL or QEL device approximately 200 times with five second hold time after each pull.:
What would cause an EL device to pull and release?
Resolution:
If your Von Duprin EL (solenoid) device pulls and releases quickly instead of holding the latch retracted, please check all of the items below.In most cases, one or more of these solutions will r...:
What BHMA Grade is the Falcon 25 Series exit device?
Resolution:
A copy of the BHMA Directory Listing can be viewed in the online Certified Directory on the BHMA web site. BHMA:
How to test the RX switch in a Chexit device.
Resolution:
Chexit devices shipped prior to 8-24-2015 with solenoid driven: If Chexit device goes into alarm with fast flashing red LED after the rearm time, the RX switch may be out of adjustment or defect...: