Question
Answer
Can I use the 8847-F on wood door?
Resolution:
The 8847-F is for hollow metal doors only and can not be used on Wood doors.:
Can the Von Duprin 9947 metal door device be converted to the 9947WDC wood door device in the field?
Resolution:
The Von Duprin 9947 metal door device can be converted to the 9947WDC wood door device by purchasing conversion kit number 050134-XX. This conversion kit is only for the panic version only. Fire ...:
What is the standard Steelcraft door thickness?
Resolution:
1 3/4" is the standard door thickness. Steelcraft only makes a nominal 1 3/4" thick door. A 1 3/8" was made for light duty commercial applications but that product was discontinued in 1999.:
Can you change 98/9947 WDC device to a 98/9947 hollow metal device?
Resolution:
Yes, for Panic devices only by ordering the top rod kit part #050574, bottom rod kit part #050575, and screw pack #090061. Fire Rated devices can NOT be converted and would require a compl...:
Can you get a metal cover on a 1461?
Resolution:
A designer series metal cover is an option with the 1460 series closer, the part number is, 1460-72DS1.Adapter Kit used to mount cover to the closer – part number: 1460-3373. ...:
Steelcraft field paint instructions
Resolution:
Steelcraft frames and doors are furnished with a high grade, low gloss, baked-on prime paint that provides the best possible protection against corrosion, abrasion and weather, and is an excellent ...:
What is the 022558-000-70?
Resolution:
DISCONTINUED: The Falcon T lock had a reinforcement kit for a 1 3/4" thick hollow metal door that prevents lateral movement of the latch. It is a piece of hard foam shaped like a doughnut...:
Can doors be prepared for raceways in the factory?
Resolution:
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 3/4" ID steel...:
What is the most common practice for running electric power from a frame to the door and hardware?
Resolution:
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into...:
What is a raceway?
Resolution:
A raceway in a door provides a clear wiring access through the door core from hinge to lock edge. In a steel (hollow metal) door, the raceway is typically a length of conduit installed during d...: