Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
Closer special templates
”
RELATED FAQS
Question
Answer
What special template (ST) is used with a 4640 operator and a deep reveal?
Resolution:
The "Regular Arm" allows for a reveal up to 4-1/2".The "Long Arm" allows for a reveal between 4-1/2"- 8".ST-3088 is a special "Extra Long Rod" used to mount a 4640 operator on an opening ...:
SPECIAL TEMPLATE
Resolution:
ST:
What special template (ST) is used with a 4040XP with a non-adjustable (solid) regular arm for pull side mounting?
Resolution:
Special Template ST-2795 is used to mount a non-adjustable (solid) regular arm for pull side mounting. :
Where are hardware templates?
Resolution:
All the templates can be found at us.allegion.com Please click here :
Can a 4040 Pull Side closer be mounted with Swing Clear Hinges?
Resolution:
ST-1583 is used to template a 4040 or 4040XP closer mounted hinge side with swing clear hinges. For current ST add on pricing and templates please contact closers_techpro...:
What special template (ST) is used with a 2030 closer and GJ over head stop?
Resolution:
Special template ST-2211 is used to mount a 2030 series closer with a GJ 70,79,81,90, and 450 series overhead stops. This ST works with any GJ "surface" mounted stop. The 2030 closer cannot b...:
What special template (ST) is used with a 4040(XP) Rw/PA mount closer and a GJ overhead stop?
Resolution:
The use of a 62A Shoe (required) would be used to mount a 4040XP Parallel Arm with a "SURFACE" GJ 70, 79, 81, 90, or 450 series stop. You would order the 4040XP with a Reg w/62A arm op...:
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.This ST also REQUIRES the use of a 4040-18TJ drop plat...:
What special template (ST) is used with a 4110 closer and GJ90 series?
Resolution:
ST-2730 is used with a 4110EDA closer and GJ901-904 overhead stop.This can only be used with GJ901-904.If a drop plate is required, a 4010-18 drop plate would be used (A 4110-18 drop plate can not ...:
What special template (ST) is used with the 2030 closer and a low profile track and roller?
Resolution:
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track. For a top rail less than 1-3/8" and as narrow as 1", you could use the l...:
Can you convert a 4041 Cush arm to a 4041 HCush arm and use the same templating?
Resolution:
The 4040XP/4041 Cush and HCush (Hold Open Cush) use the same instructions / template.:
What is the maximum degree of opening you can template a 4110 Cush closer?
Resolution:
The 4110 Cush closer can be templated for 85°, 90°, 100°, and 110° maximum as standard templates.The 4110 if ordered by ST-3220 will allow templating to 135°:
Can I mount an LCN Cush closer with an GJ overhead stop?
Resolution:
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.:
Can a 4110 EDA and a Glynn Johnson 100 be used together?
Resolution:
A special template is not needed, the closer drops down far enough on the door where it does not conflict with the GJ100 series concealed overhead stop. :
What is the mounting difference between a 2010 closer and a 2030 closer?
Resolution:
The 2010 and 2030 closer are not the same. The 2010 Series closer uses the (larger) 4010 cylinder which requires a 4" minimum frame tube to mount in. The 2030 uses the (narrow) "Pacer" cylinder...:
Does a SEH require a door closer?
Resolution:
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...:
Does LCN still make a 4010SE / 4110 SE?
Resolution:
The LCN 4010SE / 4110 SE series are obsolete, and on longer available (discontinued around Aug 1995). They were replaced by the 4040SE series.The 4010SE / 4110 SE track is replaced w...:
Can a magnet, or sentronic device, be released and close the door from a button at a desk?
Resolution:
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wiri...: