closer holder conflict chart
”
RELATED FAQS
Question
Answer
What is a 4430 / 4330?
Resolution:
The 4330 / 4430 is an obsolete ME closer replaced by the 4310ME or 4410ME Series.:
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.This ST also REQUIRES the use of a 4040-18TJ drop plat...:
What are Hold Open Closers & Magnets?
Resolution:
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions. Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...:
Where are hardware templates?
Resolution:
All the templates can be found at us.allegion.com Please click here :
How to adjust a 4010 hold open arm?
Resolution:
The correct method (process) for setting the hold open is: The 4010 hold open arms are handed, verify correct hand arm. (R or L stamped on main arm) Loosen the hold open nut. Opened the door ...:
What causes am ME Series closer to creep shut (creeper)?
Resolution:
If an ME Series closer creeps shut or will not hold open, Verify proper voltage is being supplied to the closer, if correct Check the on/off switch. Verify the voltage on the 2 pin co...: